Physical Chemistry : 2018 Transalkylation and disproportionation of 1,2,4 trimethylbenzene over faujasite zeolite- A.A.Elkahlawy- Cairo
Huge pore faujasite zeolite (Pt/H-Y) and its de aluminated structure
Articles, journals and conferences in one search. An exact title, DOI or ISSN is listed first.
In the search box: "exact phrase" · -leave out · OR · prefix* · title: author: journal:
Huge pore faujasite zeolite (Pt/H-Y) and its de aluminated structure
thermal properties were characterized by fourier transform infrared spectroscopy (FTIR), scanning electron microscopy (SEM), X-ray diffraction (XRD) and differential scanning calorimetry (DSC). The SEM analysis revealed…
shapes which included triangles, spheres, hexagons and pentagons as analyzed by high resolution transmission electron microscopy. The optimized processing parameters like salt concentration (1 mM concentration of HAuCl4…
Visible Spectrophotometer, Fourier-Transform Infrared Spectroscopy (FT-IR), Scanning Electron Microscopy (SEM), Dynamic Light Scattering (DLS) and X-ray Diffraction study. Antibacterial activity was evaluated using agar…
spectrum has been evaluated. The as-synthesized nanoproducts were characterized by X-ray diffraction (XRD), scanning electron microscopy (SEM), transmission electron microscopy (TEM), photoluminescence (PL) spectroscopy…
analysis. Secondly, the shape and size of S-NPs were investigated by scanning electron microscopy (SEM) techniques in all S-NPs samples which were prepared with Tetramethylammoniumbromide (TMAB) surfactant, Then…
microwave method and characterized by X-ray powder Diffraction (XRD), X-ray Fluorescence (XRF), Brunauer–Emmett–Teller (BET), Scanning Electron Microscopy (SEM) and Dynamic Light Scattering (DLS) techniques
composite’s crystalline structure is investigated by X-ray diffraction and FTIR, while atomic force microscopy (AFM) and scanning electron microscopy (SEM) are used to analyze the surface morphology
release studies was carried using Transmission electron microscopy (TEM) and high performance liquid chromatography (HPLC) respectively, Differential scanning calorimetry (DSC), X-ray diffraction (XRD), energy…
process the examples. The mechanical testing, sending (power and so on) electron microscopy (TEM), X diffraction (XRD), water absorption, water vapor, permeability, oxygen permeability and microbial permeability of…
synthesized CuAlO2 were investigated by adopting X-ray diffraction (XRD), energy dispersive X-ray spectroscopy (EDS), transmission electron microscopy (TEM), and field-emission scanning electron microscopy (FESEM)…
each stage of processing and consisted of investigation using Transmission Electron Microscope and Electron Backscatter Diffraction on Scanning Electron Microscope. Mechanical properties were evaluated based on tensile…
spectroscopy (UV–vis spectra), scanning electron microscopy (SEM), transmission electron microscopy (TEM), energy dispersive X-ray spectroscopy (EDS), X-ray diffraction (XRD), thermogravimetric analysis (TGA), and…
agent of polyvinylpyrrolidone. A range of analytical techniques: X-ray diffraction (XRD); energy dispersive X-ray (EDX); transmission electron microscopy (TEM); and Fourier Transform Infrared Spectroscopy (FTIR) were…
from aqueous solution. Characterizations using Field emission scanning electron microscopy (FE-SEM) , powder X-ray diffraction (XRD) , FTIR , energy dispersive X-ray spectroscopy (EDX) were carried
characterized by the field emission scanning electron microscopy (FESEM), Fourier transform infrared spectroscopy (FTIR), Brunner –Emmett –Teller (BET), and X-ray powder diffraction (XRD). The BET surface areas
Photon Source on AM samples of Ti-6Al-4V using both laser (SLM) and electron beam (EBM) powder bed; Inconel 718 and Al-10Si-1Mg from SLM were also characterized ... Keyhole depth is linearly related to the excess power…
drug. The fabricated nano composite was characterized by scanning electron microscopy (SEM), Fourier transform infrared spectroscopy (FTIR) and X-ray diffraction (XRD). Under optimized conditions, the anodic peak…
kesterite phase with a nearly stoichiometric composition. Samples were characterized by X-ray diffraction (XRD), scanning electron microscopy (SEM), EDS and UV-VIS-NIR spectrometry. X-ray diffraction and confirmed
post-expansion distortion of about 2-7%. Physical tissue expansion pushes the conventional diffraction-limited microscopes beyond their resolution limits (currently ~250nm), by enabling for the first time ~80nm…
results. Theoretical calculations and indirect experimental measurements using atomic force microscopy (AFM), X-ray diffraction analysis, inelastic X-ray scattering, Raman scattering, etc. were used to calculate the…
investigated. The scanning electron microscopy (SEM) has been conducted for blends before and after release. Crystallization behavior of EVA was investigated as well as X-ray diffraction
sintered ceramic varistors with different compositions have been characterized via laboratory X-ray Diffraction (XRD), Scanning Electron Microscopy (SEM), and electrical measurements. It has been observed that
obtained products were revealed by the modern physicochemical systems such as X-ray diffraction (XRD), Transmission Electron Microscopy (TEM) and the BET specific area surface. The amounts of silane agent
obtained materials were determined by X-Ray Fluorescence (XRF), Electronic Scanning Microscopy (SEM) and X-Ray Diffraction (XRD) analysis. The efficiency of mesoporous silica filters, obtained by powders pressing
For authors and organisers
Find the right journal for your paper and submit your manuscript.