investigate the behavior of Reinforced Concrete (R.C.) frames by using steel bracing under horizontal loading and to decrease the potential for captive-column damage. An experimental study is carried ... such frames…
study the effect of various geometrical stiffeners parameters in the critical/ultimate buckling load capacity of circular Lean Duplex Stainless Steel (LDSS) stub column loaded axially using finite element ... thickness…
main aim of this technique is to reduce the computation cost and transmission load which is applied in a concatenated location-radio signal space, and attributes different weight factors
against some faults such as over current, over voltage, higher temperature in windings, more load on motor. Therefore, controlling, monitoring, and protection of the system are realized in real time
network is applied to the three phase inverter which feeds an induction motor load. The simulation studies are performed using matlab and the results are presented
Passive LC filters have long been used to absorb harmonic current of non-linear loads. Due to some disadvantages of passive filters the concept of active filters were proposed. There
experimental and numerical investigation on the behaviour of reinforced GPC slabs under repeated impact loading. The aim is to study the impact behavior of reinforced GPC slabs with and without ... Reinforcement…
time of occurrence of peak pressure and maximum heat release] were evaluated at full load operation of the engine with alcohol blended gasoline. Comparative studies were made on performance parameters
study the different modulation techniques used for three phase VSI supplying single phase loads that require neutral connection. Two types of topology of three phase inverter, namely three ... only possible solution for…
utilise minimum fuel to generate maximum steam as per demand of load which lead to thermal power plant optimization. The main objective of this paper is to proposed data driven
forward converter that automatically reduces the current flowing through the opto-coupler under no-load condition is presented in this paper. Standby power is electricity used by appliances and equipment ... uses TL431…
Peak current mode control of a buckboost converter along with the load and transient analysis using a PIC microcontroller is done. The new elucidation includes a discrete time controller using
With an increased use of nonlinear loads, sensitive electronic equipments and variable frequency drives power quality has become a prominent issue these days. The development of new methods for detection
reactive power has to be as low as possible. For low power factor loads or low power factor generation systems a back to back bidirectional converter set is employed
shows the best performance of the distributed generation placement at/near the non-linear load buses. The balanced distribution system model is simulated using MATLAB/SIMULINK 2012 software with static ... linear loads
these kind of clean power sources to the conventional grid and also to the load. This proposed system consists of two input sources, each one connected to two different inductor
voltage multiplier increases the output level of the stepupdc-dcconverter which drives the load. The converter-voltage multiplier module provides continuous conduction with the voltage stress on cascaded capacitor-diode
performance of the MPPT controller and designed system for varying atmosphere conditions and load disturbances. Moreover, the SEPIC converter needs no current snubber for the diodes. The integrated SEPIC
transmission facilities forces the power system to be operated under stressed conditions. At heavily loaded conditions the power system must be provided with sufficient reactive power reserves in order ... instability…
Electro-Technical Commission (IEC). The STATCOM provides reactive power support to hybrid system and load. The Battery Energy Storage System (BESS) is generally required to compensate the fluctuation generated…
other equipment have led to congestion in one or more transmission lines. The network loading is maintained within the specified norms for system secure operation. Generation rescheduling and/or load
generating units in order to minimize the total cost satisfying constraints and load demand in each interval. Several conventional and evolutionary algorithms have been employed to solve this problem
duty ratio operation. This control method enables a fast transient response and efficient light-load operation while providing controlled spectral characteristics of input and Output waveforms. The resonant inductors
switches are operated in switch mode where they are required to turn the entire load current on and off during each switching cycle. Under these conditions, the switches are subjected
For authors and organisers
Publish, present and keep up with your field
Find the right journal for your paper and submit your manuscript.