mobile phase and the pH was adjusted into 4.5 by using with O-phosphoric acid, at a flow rate of 1.2 ml/min. The UV range was detected ... respectively. The different analytical performance parameters such as linearity…
detection at 263 nm. The effects of the operational chromatographic conditions on retention and resolution were tested. Different concentrations of the organic solvent in the mobile phase, the ionic strength ... NH4AC…
sensitive and precise chromatographic methods were developed and validated for simultaneous determination of metronidazole (MTR) and diiodohydroxyquin (DIQ) in pharmaceutical preparation. The techniques adopted for…
simple, rapid and sensitize high performance liquid chromatography method for determination of paracetamol in a commercial dosage from Febrinil has been developed. The SHIMADZU LC 20 AT dual ... pump chromatograph…
ions using 2- mercaptobenzothiazole (MBT) modified alumina coated magnetite nanoparticles (ACMNPs) for its highly sensitive measurement by cold vapor atomic absorption spectrometry (CVAAS). The effects of various…
used as mobile phase with flow rate of 1 mL per min. LiChrospher C18-5 μm (25 x 0.46 cm) column was used and UV detection was made ... interfere with the assay procedure. Proposed method was found to be simple…
with a mobile phase consisting of methanol: water (70:30, v/v) (pH 3.7) adjusted with ortho phosphoric acid, with a flowrate of 1ml/min, UV detection at 260 nmwas ... respectively. The method was found to be sensitive…
simple, precise, sensitive, and validated reverse phase high performance liquid chromatographic method has been developed and validated for simultaneous estimationGemifloxacinmesylate (GFM) andAmbroxol hydrochloride…
selective and sensitive high-performance liquid chromatography method has been developed and validated for determination of (3aRS,4SR,7RS,7aSR)-2-(Tricyclo-[3.3.1.13,7]decan ... achieved on a reversedphase C18 column…
simple, sensitive and isocratic reverse phase high performance liquid chromatographic (RPHPLC) method has been developed for the simultaneous determination of Phenobarbitone and Ethyl Alfa Bromisovalerianat in a…
known as Vitiligo antibodies. By using solid phase enzyme immunoassay employing recombinant human TPO and TG from eukaryatic expression system for quantitative detection of antibodies in human serum ... extent of…
albumin (IscMA) is an ideal biomarker for ischemia. It is highly sensitive and detectable in the early phase of ACS. Many clinical studies have demonstrated that IscMA can be used
simple, rapid, sensitive and precise RP-HPLC method has been developed for the estimation of zaltoprofen in tablet dosage form. In this method Phenomenax Luna ... column with mobile phase consisting of acetonitrile and…
hydroxide) in the ratio 50:50 v/v as mobile phase and at a flow rate of 1.0 mL/min. Detection was carried out using a UV detector at 302nm ... about 6.5min. The method was validated for accuracy, precision, specificity…
resultant gift is the dreaded Totally Drug Resistant Tuberculosis (TDR-TB). Culture and drug sensitivity testing (DST) should not blindly direct the management of TDR-TB, but has the importance ... part of Directly…
sensitive and selective method using quadruple tandem mass spectrophotometer interfaced with electro spray ionization was developed for the quantification of unbound drug in pretreated plasma. The mobile phases used…
simple, sensitive and compatible liquid chromatography tandem mass spectrometric method has been developed and validated for the estimation of Pyrazinamide. Glipizide was used as an internal standard. Detection was…
sensitive RP-HPLC method with UV detection for routine analysis of montelukast sodium in bulk and in pharmaceutical formulation was developed. Chromatography was performed with mobile phase containing a mixture…
Background: A simple, sensitive and rapid method was developed for quantitation of theophylline in rabbit plasma utilizing Triple Quadrupole LC/MS. Materials and Methods: An aliquot ... Column (3 × 50 mm) with a mobile…
rapid, economic, sensitive and reliable gas chromatographic method was developed and validated for the determination of residual Epichlorohydrin (ECH) in Pharmaceutical drug substances. This method ... utilized a…
order of magnitude and cures even bulky, systemic lymphoma burden Methods: We initiated a phase I/II study of immunotransplant for newly diagnosed MCL patients to test the hypothesis that ... throughput sequencing (HTS)…
mobile phase for the determination of RA and UA respectively. The flow rate was 1.0 ml min−1 and detection wavelength ... respectively. The method is simple, sensitive, reproducible and ideally suited for rapid routine…
For authors and organisers
Publish, present and keep up with your field
Find the right journal for your paper and submit your manuscript.