parent compound. The chromatographic analysis time was approximately 7 min per sample with complete resolution of Levetiracetam (tR = 5.351 min) from the major degradation products. The method was validated…
flow rate of 0.6 mL min. In the developed LC method the resolution between bortezomib and five potential impurities ... injection volume. The developed rapid LC method is validated with respect to specificity, linearity…
reported so far. The present method utilizes a simple extraction step and simultaneous HPLC resolution of Sudan I, II, III, IV and dimethyl yellow in oil rich Indian curry samples ... with the regression coefficient…
method was validated using ICH guidelines in terms of precision, repeatability and accuracy. Linearity range for Allethrine was 40–320 ng/spot and its content ... seed. This simple, precise and accurate method gave good…
simple, precise, accurate, simultaneous and stability-indicating RPLC method developed with an effective resolution for active pharmaceutical ingredients and marketed drug products. This method effectively separate all…
Methods: Patients (mean age, 75.5 years; range, 60-86) were enrolled who had AMD with a baseline Logarithm of Minimum Angle of Resolution (logMAR) Best-Corrected Visual Acuities (BCVAs
terms of specificity and sensitivity to a simple accurate mass liquid chromatography high resolution TOF mass spectrometry (LC-HRMS) method in which MS detection was carried out in electrospray positive ... precision…
Generally proteomics analysis of cyanobacteria has limited dynamic resolution because of the presence of abundant proteins. Thus proteomics assessment of the low abundance proteins in cyanobacteria is difficult…
phase composition, injection volume, mobile phase pH, flow rate, temperature, and detector wavelength on resolution was investigated. The method was validated with respect to precision, accuracy, and linearity…
resolution and minimal tailing and without interference of excipients. The retention times of ezetimibe and Atorvastatin were 5.7 min and 9.1 min, respectively. The method was linear in the range
detection at 263 nm. The effects of the operational chromatographic conditions on retention and resolution were tested. Different concentrations of the organic solvent in the mobile phase, the ionic strength…
polar surface area, formula weight, and molecular volume are determined. The range of Log P and polar surface area for the ten analogues ... formula weight, number of oxygens & nitrogens, and number of hydroxyls &…
surgically catheterizing blood vessels of rodents is possible, it is labour intensive and time resolution of blood sampling is restricted due to the limited amount of overall blood ... curves visually significantly…
nasopancreatic drain (1 case) with resolution of external pancreatic fistula in 4 to 6 weeks. Of seven patients presenting with symptomatic pseudocyst (size range: 4-14 cm), two patients were ... placed in one patient…
Probenecid(PRO) as Internal standard in human plasma samples is described. The ranges of the independent variables used for the optimization were MeCN: 30-40%, buffer conc ... these independent variables on the output…
High Resolution Transmission electron microscopy. HRTEM micrographs as well as the SPR peaks of UV-Vis spectra showed that the size of the GNPs ranged from
doxofylline (retention time = 3.4 min) and montelukast sodium (retention time = 5.5 min) with a resolution of 5.47. The proposed HPLC method was validated with respect to linearity, accuracy, repeatability, specificity…
pattern of amplification, according to the species examined. The number of alleles ranged from 1 to 6. The results demonstrate the possibility of using these heterologous markers in other Melipona ... intra- and…
imaging technique in the assessment of the scrotal contents, providing unparalleled imaging of exquisite resolution. Ultrasound is effectively the sole scrotal imaging technique that a patient will undergo prior…
normal antimicrobial activity. Current methods for assessing the ASL have important flaws (temporal resolution, dilution factors, collection volume), which have been a recurring obstacle for understanding diseases in…
fluoro acetic acid (98:1.5:0.5:0.1 v/v/v/v). The resolution between the two enantiomers was found to be more than 2.0. The limit of detection ... respectively, for 10 μL injection volume. The percentage recoveries of…
sensor. The ASIC works with lowvoltage and low-current, with wide operating temperature range. The bio-sensor, which was designed very much sensitive to room temperature and pressure. Nano ... nano-amps or pico-amps…
dioptric spherical equivalent and mean preoperative best corrected visual acuity was 1.25 log MAR (range 1.6 to 0.5). Mean follow-up was six months. Results: Fourteen eyes (77.7%) of eighteen ... BCVA at last follow-up…
with treatment intervention at an average of 8.75 months post-fracture (range 4- 18 months, one patient fracture not included in calculation was >100 mo.). All treated patients received autologous ... fracture…
performed at 245 nm. A calibration graph was plotted which showed a linearity range between 1-5 μg/ml with the correlation coefficient ... same optimum conditions. The system suitability studies were also calculated…
For authors and organisers
Publish, present and keep up with your field
Find the right journal for your paper and submit your manuscript.