simple, rapid, sensitive, specific, accurate, HPLC method was developed and validated as per ICH guidelines for the determination of ofloxacin in eye drop. Thermoseparation products
present study describes the development and subsequent validation of accurate, precise and reproducible HPLC and HPTLC methods for the analysis of Pravastatin (I), Simvastatin (II) and Ezetimibe (III) at ambient…
benzene (TMB) and also its starting material anisole as an impurities.Asingle analytical method was developed for the separation of all theses impurities including six positional isomers with the quantitation ... than…
simple, fast, precise and accurate high performance thin layer chromatographic method has been developed for the simultaneous determination of Bambuterol HCl usingMebeverine HCl as an internal standard. Chromatographic…
simple, fast and precise high performance thin layer chromatographic method has been developed for the simultaneous determination ofCamylofin dihydrochloride usingMebeverine as an internal standard. Chromatographic…
having high accuracy, precision and reproducibility was developed for the routine estimation of Gatifloxacin in the tablets available in market and was validated for various parameters according to ICHguidelines…
Anew, rapid and sensitive reverse phase HPLC method was developed and validated for the determination of benzhexol hydrochloride in tablet formulations and urine. The mobile phase used acetonitrile and water
simple and sensitive kinetic spectrophotometric method has been developed and validated for the determination Lisinopril in bulk drug and in its pharmaceutical tablets. Themethod was based on the oxidation
validated specific stability indicating reversed-phase HPLC method was developed for the quantitative determination of Amsacrine as well as its related substances determination in bulk samples, in presence of…
Asimple and rapidHPLCassay for ampicillinmeasurement in human plasma was developed and validated. 0.25 ml plasma sample was precipitated with 50 µl of perchloric acid, and 100 µl of the supernatant
case was close to 99.9%, indicating that the developed method was stability-indicating. Validation of the developed method was carried out as per ICH requirements. The proposed RP-HPLC method
oxidation process was shown to be irreversible and adsorption-controlled. An analyticalmethod was developed for the determination of cibacron red FNR in phosphate buffer solution at (pH 3.34) as supporting ... limit of…
Simple, sensitive, selective and precise spectrophotometric, spectrodensitometric and HPLCmethods were developed and validated for the simultaneous determination of allopurinol (AL)&benzbromarone (BZ) in presence of…
novels simple, accurate, sensitive and reproduciblemethods have been developed and subsequently validated for the determination of itopride Hydrochloride in presence of its acidic and oxidative-degradates, as stability-…
simple, accurate, rapid and reproducible methods have been developed and subsequently validated for the determination of Levetiracetam in presence of its acidic and alkaline-degradates, as stability-indicating studies
simple, accurate, sensitive and reproducible methods have been developed and subsequent validated for the determination of Dothiepin Hydrochloride in presence of its oxidative and photo-degradates, as…
simple, fast and precise reversed phase high performance liquid chromatographic method has been developed for the simultaneous determination of Camylofin dihydrochloride and Nimusulide usingMethylparaben as an internal…
Tinidazole and Ciprofloxacin hydrochloride in a combined formulation of the two has been developed using differential pulse polarography. Both tinidazole and ciprofloxacin produce a cathodicwave at -0.48 Vand…
rapid, accurate and reproducible method was developed for quantitative determination of thirteen explosive compounds in soil at trace levels (µg/ kg) by gas chromatography-ion trap mass spectrometry. Explosives were…
performance thin layer chromatographic method of analysis ofArbidol as a bulk drug was developed and validated. Themethod employed TLC (Thin Layer Chromatography) aluminumplates pre-coated with silica gel 60 F254
describes an in-house validated GCMS method for quantitative determination and confirmation for the TBHQ, BHA and BHT in vegetarian ready to eat meals. Develop and optimised simple and rapid
present study, an attempt has been made to develop a simple method for the simultaneous determination of ofloxacin and ornidazole usingDifferential Pulse Polarography (DPP) technique. Quantification of ofloxacin and…
Kerala and Tamil Nadu. In present study, a HPTLC method has been developed and validated for simultaneous determination of â-sitosterol and Lupeol in the bark powder of Artocarpus lakoocha ... asmobile phase. After…
followed by 35°C /min up to 260°C for 2 minuets. The developed method was validated with respect to linearity, accuracy, precision, specificity, ruggedness and robustness
phenols, polycyclic aromatic hydrocarbons (PAHs), and heterocyclic compounds.A unique stability- indicating HPLC method was developed for the quantitative determination of%coal tar by quantification ofmarker peaks viz…