rapid and sensitive RP-HPLC method with UV detection and UV spectrophotometric method for routine Pharmaceutical quality control of aceclofenac, paracetamol and tizanidine in tablets formulation was developed…
gene. Th e S-OIV RTLAMP was 10 fold more sensitive than WHO realtime RTPCR with a detection limit of 0.1 TCID 50/ml. Th e comparative evaluation of RTLAMP ... assay vis-a-vis WHO real-time RTPCR was undertaken with 1000…
sensitive extraction method was developed using the mixture Methanol- Dichloromethane-Water (MDW) (0.3:4:1v/v/v) and MeOH-H2O phase was assayed for sugar analysis. Photodiode-array detection
develop and validate a simple, sensitive, precise and specific reverse phase high performance liquid chromatographic method for the determination of prasugrel in bulk and tablet dosage forms. The HPLC separation…
methods used for analysis of trace amounts of drugs. A rapid, sensitive, and specific reverse phase ultra-performance liquid chromatographic (UPLC) method was developed for the quantitative determination of duloxetine…
ratio of 35:65 v/v and mobile phase pumped at a flow rate of 0.6 mL/min with PDA detection at 227nm. The linearity range was found ... method was successfully validated and it was concluded that the developed method was…
develop and validate a rapid and sensitive reverse phase high performance liquid chromatography (RP-HPLC) method with UV detection for quantification of meta-cresol (m-cresol) in pharmaceutical preparation
Purpose: This study was designed to develop and validate a simple, sensitive, precise, and specific reverse phase high-performance liquid chromatographic (HPLC) method for the determination of prasugrel in bulk…
Objective: A simple, precise, reliable, rapid, sensitive and validated RP-HPLC method has been developed to determine esomeprazole magnesium trihydrate (ESO) and naproxen (NAP) in synthetic mixture form. Materials…
rapid and sensitive reverse phase high performance liquid chromatography (RP-HPLC) method has been developed for estimation of Granisetron hydrochloride in bulk and pharmaceutical dosage forms. Granisetron hydrochloride…
quick and sensitive reversed phase high performance liquid chromatography (HPLC) method has been developed in Indian surgical patients to determine the concentration of Propofol In human plasma. Propofol ... column…
simple, selective, rapid, precise, sensitive and accurate HPLC method has been developed for the estimation of nitrendipine in tablet dosage form. The method was carried out on a Phenomenox ... mobile phase( pH was…
with a mobile phase consisting of methanol: water (60:40 v/v), pH adjusted to 2.8 with orthophosphoric acid and flow rate of 1.0 mL/min. Detection was carried ... good agreement with label claim. The developed method…
analysis was carried out using a phenomenax C-18, pre-packed column. A mobile phase containing a phosphate buffer (pH 5.5) : Methanol : Acetonitrile : Tri-ethylamine (40 : 40 : 20 : 1.5), with ... detection at 257 nm…
simple, sensitive and precise reverse phase high performance liquid chromatographic method (RP-HPLC) has been developed and validated for the simultaneous estimation of paracetamol and drotaverine hydrochloride in both…
simple, sensitive and rapid method was developed for quantitation of tacrolimus in rat whole blood utilizing triple Quadrupole LC/MS. An aliquot of 0.1 mL of whole blood sample ... 2mmX50mm.i.d) column with a mobile…
presence of its degradation products. Materials and Methods: An accurate, sensitive, precise, rapid, and isocratic reversed-phase high-performance liquid chromatography (RP-HPLC) method, equipped with a photo-diode…
material and its tablet dosage form. Separation was done by using mobile phase consisting of HPLC grade water and methanol in a ratio of 75:25. The separations were carried ... rate of 1 mL/min.The injection volume was…
rapid, sensitive and specific RP-HPLC method involving UV detection was developed and validated for determination and quantification of (DMAPIMP)2Zn . Chromatography was carried out on Waters 2695 separation module…
accurate, sensitive high performance liquid chromatography method for the simultaneous determination of Tenofovir disoproxil Fumarate (TNF) and Emitricitabine (EMT) in dosage form was developed and validated as per ICH…
simple, sensitive, precise and specific reverse phase high performance liquid chromatographic method was developed and validated for the determination of Palonosetron Hydrochloride in bulk and softule dosage forms…
sensitive, accurate and rapid reverse phase Liquid chromatography/tandem mass spectrometry (LCMS/MS) method was described to estimate acyclovir in human plasma. Detection was made
simple sensitive and precise high performance liquid chromatographic method for the analysis of naproxen and pantoprazole has been validated and used for the developed, validated and used for the determination…
Agilent) at an ambient temperature. Elution was performed with a mobile phase consisting of acetonitrile (solvent A) and a mixture of 10 gm of sodium lauryl sulphate ... ratio of 70:30 v/v and a flow-rate of 1.7 ml/min…
For authors and organisers
Publish, present and keep up with your field
Find the right journal for your paper and submit your manuscript.