Search Scholars Central
Articles, journals and conferences in one search. An exact title, DOI or ISSN is listed first.
Advanced searchHide advanced search
In the search box: "exact phrase" · -leave out · OR · prefix* · title: author: journal:
Research article · 2012 Research article · 2012 Green Synthesis of Biodiesel from Various Vegetable Oil and Characterisation by Ft-IR Spectroscopy
ethyl ester of vegetable oil. Confirmation of the biodiesel was done on FT-IR spectrometer. The IR value ranges from 1741 to 1743 cm-1, which clearly indicates carbonyl group
Research article · 2012 Kinetic and thermodynamic study of eosin Y dye biosorption by leaves of date palm (Phoenix dactylifera L.)
palm of Phoenix dactylifera L. The concentration of dye was determined by a UVvisible spectrometer. In this study The effect of contact time, pH of solution, adsorbent dosage, initial eosin
Research article · 2012 Fly ash generated from heavy fuel incineration in power plants: Physical and chemical characteristics
transforminfrared spectroscopy (FTIR), lazier diffractometer (LD), Thermal gravimetric analysis (TGA) and acoustic and electroacoustic spectrometer in order to investigate geometrical structure, morphology, surface…
Article · 2012 In vitro bioaccessibility as a tool to test improved cultivars performance with higher levels of â-carotene from foods
high performance liquid chromatography (HPLC)withYCM®C30CarotenoidS-3 4.6 x 250mmcolumn and UV-Vis spectrometer. Therefore, thismethodology proved to be faster and cheaper, inasmuch as in vivo studies are more
Research article · 2012 Fourier Transform Infrared Spectroscopic Characterization for Detecting Soil Minerals and Toxicological Effects of Selected Minerals in Soils
Infrared (IR) spectrometry is the study of the interaction of infrared light
Research article · 2012 Novel analytical reagent for the quantification of Mn(II) in various water systems
BMBPD)was synthesized for the determination of Mn(II) in various environmental samples with spectrometer. The method was based on chelation of Mn(II) with
Research article · 2012 Physico-chemical parameters and elemental analysis of the soils of sunflower (Helianthus annus. L) growing field with different manure treatment
important trace elements viz., Fe, Zn, Mn and Cu are estimated using Atomic Absorption Spectrometer (AAS). The results of the Physico-Chemical parameters, the concentrations of trace elements and their
Research article · 2012 Evaluation and determination of toxic metals (Lead and Cadmium)in cow milk collected from East Azerbaijan, Iran
accomplished with the help Spectrometry of atomic absorption using a Varian AA220 atomic absorption spectrometer (Australia). The highest concentration of cadmium was found in the Sarab city
Research article · 2012 Rapid Equilibrium Dialysis (RED): an In-vitro High-Throughput Screening Technique for Plasma Protein Binding using Human and Rat Plasma
Water with gradient HPLC method. The unbound fraction of drugs was detected by mass spectrometer operated in ESI mode. In addition, data for a set of ten compounds was compared
Research article · 2012 The collision/reaction cell and its application in inductively coupled plasma mass spectrometry for the determination of radioisotopes: A literature review
C2H2, and CH3F in an inductively coupled plasma collision/reaction cell mass spectrometer (ICP-CRC-MS) are reviewed
Research article · 2012 Simultaneous Multi-Element Determination of Bismuth (Bi), Antimony (Sb), and Selenium (Se)
biological samples by a multi-element graphite furnace atomic absorption spectrometer (Perkin-Elmer SIMAA 6000). Two types of modifiers; Pd+Mg mixture modifier and Ir as a permanent modifier, were
Research article · 2012 Synthesis and characterisation of zeolite a for adsorption refrigeration application
from metakaolin of quality Kankara kaolin and their characterization by XRF, XRD and FTIR spectrometer. The morphology was examined using SEM. Thermal analysis was followed by performing
Research article · 2012 Study of collective bands in 154Gd using IBM-1
Recently 8π spectrometer is used to identify Kπ = 01 +, Kπ = 02 +, Kπ = 21 +, bands of Gadolinium isotope. In this work excited Kπ = 01 +, Kπ = 02 +, Kπ = 21 + bands in 154Gd
Research article · 2012 Determination of Pyrazinamide in Human Plasma Samples Containing Fixed Dose Combination Molecules by using Liquid Chromatography Tandem Mass Spectrometry
used as an internal standard. Detection was performed using TSQ Quantum Discovery max mass spectrometer with ESI source in positive polarity. The detection transition for Pyrazinamide
Review article · 30 Dec 2011 Plant mediated synthesis of silver nanoparticles - tapping the unexploited sources
reddish brown. Further, a peak between 400nm to 440nm was obtained on UV-Vis spectrometer which confirmed the biosynthesis of silver nanoparticles. Presence of silver nanoparticles was observed after carrying
Research article · 30 Dec 2011 Antibacterial effect of Salvia officinalis Lam extract
extract was analyzed by Gas Chromatography (GC) and gas chromatography connected to mass spectrometer. By calculating suppressive indices it was clear that there are 10 various compounds in the extract
Short communication · 16 Sep 2011 Alcaligenes-The 4T Engine Oil Degrader
analysis was performed using a MS 5973 spectrometer coupled to 9 Hewlett Packard model 6890. I4 isolate microorganisms degraded around 76% of 4T engine oil. Gas chromatography showed significant differences
Research article · 31 Jul 2011 Measurement of mass and linear attenuation coefficients of gammarays of Al for 514, 662 and 1280 keV photons
gamma-rays photons have been measured using the well-type scintillation spectrometer. The values of μ and μ/ρ thus obtained are found to be in good agreement with
Research article · 31 Jul 2011 Assessment of copper residue in cocoa pods and beans in cocoa growing areas in the central region of Ghana
copper fungicide served as a control. Analysis for copper was done using atomic absorption spectrometer. The concentration of copper in the pods ranged from
Conference abstract · 5 Jul 2011 Accurate measurement of oxygen consumption in ventilated patients undergoing cardiac catherization and after cardiac surgery
rapid and simultaneous measurement of multiple gas fractions. The AMIS 2000 quadrupole respiratory mass spectrometer system has been adapted to measure VO2 in patients under mechanical ventilation with during cardiac
Research article · 31 May 2011 Development of a simple UV Assay method for Artesunate in Pharmaceutical Formulations
presence of two prominent peaks. The peaks were further identified with HPLC-mass spectrometer to possibly be those of glycal and furanose acetal. The method was validated for stability, linearity
Research article · 28 Apr 2011 Development and validation of the liquid chromatography-tandem mass spectrometry method for quantitative estimation of candesartan from human plasma
protonated analyte was quantitated in positive ionization by multiple reaction monitoring with a mass spectrometer. The mass transitions m/z 441.2 → 263.2 and 260.2 → 116.1 were used to measure candesartan
Research article · 17 Mar 2011 Determination of Benzoic acid Residue from Fruit Juice by Gas chromatography with Mass spectrometry Detection Technique
simple and reliable Gas chromatography-Mass spectrometer method was developed for the determination of Benzoic acid in fruit juice. Chloroform was used for extraction solvent and coextractive was removed
Research article · 2011 Structural Characterization and Biocompatible Applications of Graphene Nanosheets for Miniaturization of Potentiometric Cholesterol Biosensor
atomic force microscope and transmission electron microscope. Ultraviolet-visible absorption and Fourier transform infrared spectrometers have been used to confirm the presence of the graphene nanosheets and their…