simple, accurate, sensitive and validated RP-HPLC method for simultaneous determination of Artesunate and Amodiaquine in combined tablet dosag e form has been developed. Separation was carried out on Jasco ... phase of…
simple and sensitive liquid chromatography/tandem mass spectrometry method was developed and validated for determining rosuvastatin in human pla sma, a new synthetic hydroxyl methyl glutaryl- coenzyme a reductase…
nitazoxanide and ofloxacin. So second method carried out on same column but different mobile phase which consisting the acetonitrile: 0.2M potassium dihydrogen phospate: methanol in ratio ... adjusted with…
simple, rapid, sensitive, reverse phase isocratic RP-HPLC method was developed for determination of Valsartan in tablet dosage form. The method was carried out using Thermohypersil ODS column ... size) with mobile phase…
simple, rapid, sensitive, reproducible and precise high performance liquid chromatographic method has been developed for the estimation of rosuvastatin in pure form as well as in pharmaceutical dosage form ... with…
simple, sensitive, rapid, and reproducible RP-HPLC chromatographic method has been developed for the estimation of diclofenac and metaxalone in pharmaceutical formulation. Chromatography was carried out on an isocratic…
flow rate of 1.5ml / min and having sensitivity of 0.2. The elution is carried out using a mobile phase consisting of methanol l80 ml, Acetonitrile 180 ml, Tetrahydrofuran ... Trifluroacetic acid (0.5%) 600 ml. The…
utilizing a mobile phase of ammonium acetate buffer (pH 6.8) and acetonitrile (85:15 v/v) with UV detection at wavelength 252 nm at the flow rate ... proposed method was validated for sensitivity, selectivity…
rapid, sensitive and specific RP-HPLC [1-5] metho d involving UV detection was developed and validated for determination and quant ification of Lamivudine and Zidovudine. Chromatography was carried ... filtered and…
anatase to rutile phase of TiO 2 . Urea concentration in the electrolyte was determined by observing chronoamperometry response on urease immobilized working electrodes. The urea detection sensitivity
mobile phase. UV detection was performed at 258 nm. The method was validated for linearity, accuracy, precision, specificity and sensitivity as per ICH norms. The developed and validated method
simple, accurate and sensitive analytical methods have been developed for the simultaneous determination of Rabeprazole and Domperidone in pharmaceutical solid dosage form. The first method involves…
novel, simple, sensitive and precise RP-HPLC method has been developed and validated for quantitative analysis of amiloride and furosemide in human plasma. Use of a Inertsil ... adjusted with sodium hydroxide as…
rapid, selective and sensitive isocratic reversed-phase HPLC assay coupled with UV detection for quanti fi cation of ketorolac in serum and synovial fl uid samples has been developed. Analytes ... synovial fl uid…
widely believed that discovery of specific, sensitive and reliable tumor biomarkers can improve the treatment of cancer. The goal of this study was to develop a novel fractionation protocol targeting ... Hydrophobic…
rapid and sensitive liquid chromatography – tandem mass spectrometry (LC-MS/MS) method for determination of the Paclitaxel in human plasma was developed and validated.Placitaxel was extracted from plasma ... Column…
rapid, sensitive and specific RP-HPLC method involving UV detection was developed and validated for determination and quantification of Moxifloxacin HCl in tablet dosage form. Chromatography was carried ... column using…
column (250mm x 4.6 mm, 5μm) as stationary phase with a mobile phase comprising of 0.05 M KH 2 PO 4 in water : Methanol ... flow rate of 1.5mL min -1 , column temperature of 27°C and UV detection at 220 nm. The…
drugs was achieved on a Phenomenex column (200mm×4.6 mm, 5μm). The mobile phase consisting of a mixture of 0.1 M phosphate buffer adjusted to pH 5.5 and acetonitrile ... analysis of GFC and AMB. The wide linearity…
methanol-acetate buffer-acetonitrile (33:27:40, v/v) as a mobile phase, and spectrophotometric UV detection at 254 nm. The method has been validated for cream formulations containing betamethasone ... results…
simple, specific and sensitive high-performance liquid chromatography (HPLC) method has been developed for the determination of metoprolol in rabbit plasma. Separation of metoprolol and atenolol (internal standard) was…
this study, new, sensitive, simple and validated solid-phase extraction method is developed for the determination of nickel. Nickel was preconcentrated as 4-(2-Pyridylazo) resorcinol chelates (Ni-PAR) fromsample…
behavior of ziprasidone hydrochloride by LC-MS/MS ,and hence to develop a new, sensitive, stability indicating gradient UHPLC Related substances & assay method for the quantitative determination of ziprasidone…
Asimple, sensitive high-performance liquid chromatography (HPLC) assay for atorvastatin measurement in human plasma was fully validated, and atorvastatin stability was studied. After one-step extraction of 1ml plasma…
For authors and organisers
Publish, present and keep up with your field
Find the right journal for your paper and submit your manuscript.