mobile phase. The method was found linear in a range of 160–560 nanograms/spot for LORN and 10 000–35 000 nanograms/spot for PCM with a correlation coefficient
phenomenex C18 column (250 x 4.6 mm i.d., 5 μm particle size) using mobile phase composed of 0.5% formic acid-methanol-acetonitrile ... Results: The method was linear in the concentration range of 60-600 μg/ml for EPR…
Correlation coefficients for linearity of assay and related substances were 0.9999 and 0.9977 respectively. The low value of the RSD expressed the good repeatability and precision of the method ... respectively…
buffer : acetonitrile (50 : 50) as the mobile phase at a flow rate 1.0 mL/min. The analyte was monitored using PDA detector at 220 nm. The retention time ... bupivacaine hydrochloride. The proposed method was found to…
particle size 5 µm) column with a mobile phase consisting of methanol : water (pH adjusted to 3.34 with 0. 1% ortho-phosphoric acid) in the ratio ... method was proved to be accurate and precise at linearity range of…
performance liquid chromatographic (HPLC) method of analysis of Atorvastatin Calcium in pharmaceutical dosage form was developed and validated. The chromatographic conditions comprised of a reversed-phase C18 column…
simple, precise, reliable, rapid and reproducible reversed phase–high-performance liquid chromatography method was developed and validated for the simultaneous estimation of Paracetamol (PCM) and Lornoxicam (LOX)…
dosage forms. Materials and Methods: An isocratic reversed phase high-performance liquid chromatographic (HPLC) method with ultraviolet detection at 268 nm has been developed for the determination of amlodipine besylate…
HPLC) method has been developed for estimation of a recently approved antiepileptic drug, Levetiracetam in raw material and its tablet dosage form. Separation was done by using mobile phase consisting ... coefficient of…
work describes a simple, accurate, precise and reproducible reverse phase High Performance Liquid Chromatographic method for simultaneous estimation of Metoprolol and Telmisartan in tablet dosage form ... equation and…
HiQSil column using methanol: acetate buffer (60:40 v/v) mixture as a mobile phase of pH 6.5 adjusted with Glacial acetic acid. The detection of the combined dosage form ... method was excellent over a concentration…
content are other objective of this study. The experimental methods involved the preparation of osmotic pump capsule by phase inversion technique, utilizing a hydrophobic plasticizer castor oil. The morphology…
simple and rapid HPLC method was described for the simultaneous determination of Formoterol fumarate and Fluticasone propionate in Metered Dose Inhaler formulation. The assay involved an isocratic elution of these…
isocratic reversed phase high-performance liquid chromatographic (RP-HPLC) method has been developed for the simultaneous determination of captopril and diuretics (furosemide and hydrochlorothiazide) in API, dosage…
spectrodensitometric method, where the drugs together with AD and GD were applied on silica gel 60F 254 plates and a mobile phase consisted of chloroform: methanol: ethyl acetate: acetic acid ... calibration plots…
simultaneous estimation of tranexamic acid and mefenamic acid in combined tablet dosage form. The method employs precolumn derivatization using 0.2% methanolic ninhydrin at primary amino group of tranexamic acid…
simple, sensitive, reliable and rapid reversed-phase high-performance liquid chromatographic (RP-HPLC) method has been developed and validated for the determination of pitavastatin calcium using paracetamol as internal…
acetonitrile (10:10:5:10) asmobile phase. Method was found linear in a range of 90 monograms to 550 nanograms with a correlation coefficient > 0.99. The regression equation
phaseAwas 0.005MHeptance sulphonic acid and 0.05MDibasic phosphate buffer of pH 3.0. Mobile phase B was acetonitrile. UV detection was performed at 254 nm. The chromatographic columnwasHypersilC18,Hyper bond…
columnwith potassiumdihydrogen orthophosphate and acetonitrile (60:40 v/v) asmobile phase at 297 nmdetector wave length. The UV method was performed at 297 nm using methanol as solvent. The linearitywas ... Âg/ml for…
separation was performed on an Kromosil, 5μ , 100×4.6mm column with a mobile phase consisting of 5mM Ammonium acetate pH 3.5 : Acetonitrile (10:90v/v) at a flow rate ... were used for quantification of rosuvastatin. The…
acetonitrile (10:10:5:10) as mobile phase. Method was found linear in a range of 9-54 nanograms with a correlation coefficient >0.99. The regression equation
Thermohypersil ODS column (150 mm × 4.6 mm i.d., 5 μm particle size) with mobile phase comprised of water: acetonitrile: glacial acetic acid (500:500:01). The flow rate ... 273nm. The retention time of valsartan was…
pharmaceutical dosage form. In this method, RP-C18 column (100 mm x 4.6 mm I.D., 3 µm particle size) with mobile phase consisting of 0.02M phosphate buffer ... shows a correlation coefficient of 0.994. The retention…
Chromatographic (HPLC) method of analysis of Terlipressin in pure a nd pharmaceutical dosage form was developed and validated. The chromatographic condit ions comprised of a reversed-phase C 18 column ... value of…