pump and variable wavelength programmable UV-visible detector SPD-10AVP and a Chromosil C18 column (250 mm x 4.6 mm, 5μ) column. Methanol, acetonitrile and water in the ratio ... wavelength of 260nm. 20μl of the…
under stress conditions was achieved on YMC Pack C8, 250 X 4.6 mm, 5μm column using a gradient mixture of solvent A (0.01 M of Sodium Di hydrogen Orthophosphate
pharmaceutical dosage form. The estimation was carried out on Inertsil ODS C-18, 5μm column having 250 x 4.6mm internal diameter column with a mixture of methanol: acetonitrile
chromatographic separation using a 250 mm x 4.6 mm, i.d. C18Lichrosorb™ 10μm analytical column. The mobile phase consisted of phosphate buffer [pH: 4]: methanol: acetonitrile: triethylamine
light and UV light, two major decomposed products were successfully resolved on a C18 column (waters spherisorb 25 cm × 4.6 mm,5μm),utilizing mobile phase of tetra butyl ammonium hydroxide
Multivitamin & Multimineral unit dosage form. The separation was achieved on a reverse phase C18 column (5μm; 250x4.6 mm i.d.) with an isocratic mobile phase elution order at a flow rate
analysis of Lopinavir in bulk drug. Chromatographic separation achieved isocratically on a C18 column (Use Symmetry C18, 150 X 4.6mm, 5μ) utilizing a mobile phase of Acetonitrile: Methanol: Phosphate
method for routine analysis. The chromatographic separation was achieved on a Xterra RP-18 column (150 × 4.6 mm, 5μ) using a mobile phase consisting buffer prepared with 0.005 mole
article which we have provided improved reaction conditions, which ex-cluded the usage of column chromatography, and an overall yield of 60% with 99.9% HPLC purity has been achieved
developed for the separation and determination of the studied drugs using a C18 column. The mobile phase is composed of 0.02 M phosphate buffer (pH 2.9): acetonitrile: methanol
analysis of Drotaverine in the presence of its degradable products using C18 column. Mixture of methanol and ammonium acetate (0.1 M, pH 5) in the ratio
Based on phytochemical studies, ethyl acetate extract of Clerodendrum viscosum roots was subjected to column chromatography and eluted successively with chloroform and methanol mixture. The fractions obtained were…
hydroxide solution) and acetonitrile 65:35 compositions on reverse phase Lichrosphere RP-100 C8 column. The RSD was observed to 0.21 percentage and linearity range of (LOQ) 0.025 – 150 percentage
Quantitative Estimation of Rimonabant in pharmaceutical preparation. Isocratic separation was accomplished using C18 column (250 mn x 4.6 mm, 5 μm particle size) with mobile phase consisting of acetonitrile…
tablet dosage form with greater precision and accuracy. Separation was achieved on C18 column (250X4.6mm i.d.,5μm) in isocratic mode using Acetonitrile:Methanol:Water in the ratio ... mobile phase, pumped in to the…
separation was carried out on Hypersil BDS C18 (200x 4.6mm i.d., 5μm) column using acetonitrile: 0.05 M potassium dihydrogen orthophosphate (adjusted to pH 3.5 with ortho phosphoric acid
achieved on a Acquity UPLC BEH, C18,100 x 2.1 mm, 1.7um column. The mobile phase consisted of buffer, acetonitrile and methanol delivered at a flow rate
tablet dosage form with greater precision and accuracy. Separation was achieved on C18 column (250X4.6mm i.d.,5μm) in isocratic mode using Acetonitrile:Methanol:Water in the ratio ... mobile phase, pumped in to the…
capsule dosage form on Egilent TC C18 (2) 250 x 4.6 mm, 5 μ column using mobile phase composition of water: acetonitrile (20:80 v/v) pH adjusted to3. Flow
For authors and organisers
Publish, present and keep up with your field
Find the right journal for your paper and submit your manuscript.