Cyclization of biologically active furan derivatives
The present work involved cyclization of imines by reaction with chloro-methylene
Articles, journals and conferences in one search. An exact title, DOI or ISSN is listed first.
In the search box: "exact phrase" · -leave out · OR · prefix* · title: author: journal:
The present work involved cyclization of imines by reaction with chloro-methylene
Chromatographic separation of ZLT and its degradation products was achieved on a C18 analytical column with 0.01 M Potassium dihydrogen phosphate – acetonitrile, 80:20 (v/v), as mobile phase ... flow rate was 1.0 mL…
injector temperature set at 220°c and FID-detector set at 240°c. The column temperature was 50°c for 5min, further the temperature ramp set at 15°c /min
dihydrochloride(MPBA) content in Imatinib Mesylate on YMC –Basic, 250 X 4.6 mm 5mm column using a gradient mixture of solvent A ( 10mM ammonium formate , adjust
Compound (G1) has been isolated from Citrus laurantifoia L. fruits by column chromatography using n-Butanol : Acetic acid : Water (4:1:5, upper layer) as eluent. The possible antibacterial activity
flow rate of 1.0 mL/min over C-18 (ODS, 250 x 4.6 mm) column at ambient temperature. The retention time was found
radiation and thermal conditions. The degradation products were analyzed by HPLC using C-18 column (25 cm × 4.6 mm, 5 μm, Phenomenex Inc.). Forced degradation of the drug product
from bulk and formulations. Chromatographic separation was achieved isocratically on a Hiber@ Lichrosphere ® C18 column (250×4.6 mm, 5 μ particle size) using a mobile phase, Methanol and Potassium
employed on a symmetry Chromosil C18 (250x4.6mm, 5μm in particle size) column at ambient temperature. The mobile phase consisted of Methanol: Acetonitrile
using RP-HPLC method is simple, accurate, selective and economic by using c8 column (BDS Hypersil, 100×4.6mm,5μ particle size). Sample was analysed using water which is adjusted
Amoldipine besylate using the DB-FFAP, 30 m x 0.53mm ID, 1.0 μm column as stationary phase. The injection volume of samples taken is 1 μl. The split ratio ... 260ºC respectively. Nitrogen gas having make up flow 40 ml/…
with orthophosphoric acid , with a flow rate of 0.3mL/min, C-18 column & UV detection at 225nm.The method was validated for linearity, accuracy, ruggedness, robustness, precision & bench top stability
impurities was achieved on a YMC-Pack Pro-C18, 150 mm × 4.6 mm, 3μm column using a gradient mixture of solvent A (mixture of 0.015 M citric acid monohydrate
first method based on reverse phase liquid chromatography by using Qualisil BDS C18 column (250 mm X 4.6 i.d., 5 μm). Mobile phase consists of 1.0 ml of triethylamine
HPLC using LiChrosorb RP-8, 250 mm x 4.6 mm, 5 μm column and UV detection at 274 nm. The elution was achieved isocratically with a mobile phase consisted
pharmaceutical formulations. The separation of impurities from lacosamide was accomplished on HSS C18 Column using (100 x 2.1mm, 1.8μm) 0.01 M mono basic potassium phosphates for adjusting
form by Reverse phase HPLC method. Chromatography was carried out on a C-18 column (250 mm×4.6 mm,i.d. 5 μm) using Acetonitrile:0.05 M Ammonium Acetate buffer
dosage form. The LC method is carried out on a Waters Acquity, BEH, C8 column (100 × 2.1 mm i.d.), maintained at 25°C. The mobile phase consisted of 2.72 grams
been developed for the estimation of Dronedarone in tablet dosage form. A symmetry C18 column having dimensions of 150×4.6mm and 3μm particle size, with mobile phase containing ... adjusted to 6.8 with sodium hydroxide…
precipitated with ethanol then hydrolysed by sulphuric acid. After analysis with Gas Liquid Chromatography, Column and Paper chromatographic analysis of hydrolysate was to be composed of D-galactose
acid. The detection was carried out at wavelength 248 nm. The ZORBAX Eclips XDB column showed the most favorable chromatographic parameters for analysis. The method was validated for system suitability
antibacterial compound of the plant was conducted. For purification of antibacterial compound, open column chromatography was conducted and ethyl acetate, hexane and ethanol are used as the mobile phase ... results…
impurities in Malathion on YMC-Pack ODS AQ 250 X 4.6mm 5μm column using a gradient mixture of solvent A ( Milli Q water, adjust the pH of the above
condition, high yields, one pot reaction and simple product isolation method without use of column chromatography are the noteworthy aspects of the synthetic route. Mechanistic route of the reaction proves
isolated from the stem exudate of Brachystegia eurycoma Harms by making use of Column and Thin Layer Chromatography as separation techniques. It was then characterized by Infrared Spectroscopy, Proton Nuclear
For authors and organisers
Find the right journal for your paper and submit your manuscript.