sort to explore the effect of green tea on Metformin uses both in-vitro dissolution test and in-silico docking interactions models. Dissolution test was carried out on Metformin alone ... Metformin in the presence of…
self-nanoemulsifying drug-delivery system (SNEDDS) has been explored to improve the solubility and dissolution profile of poorly soluble drug clopidogrel. Different formulations were prepared using different oils…
evaluation tests including visual inspection, hardness, friability, disintegration, weight variation, drug content and dissolution. Tablets showed no variations in color, shape, texture and presence or absence of odor…
thickness, weight variation test, hardness test, friability test and drug content. In vitro dissolution studies carried out in 6.8 phosphate buffer using the apparatus type 2 paddle type as described ... dissolution…
combination product with the highest polymer ratio gave the best result of 3.70 mV. Dissolution studies were carried out using a twin buffer system showed a minimal drug release during
ranges from 64% to 70% and drug loading capacity range from 31% to 42%. Dissolution studies were carried out using phosphate buffer pH 7.4. The percent cumulative release of glibenclamide
upon mild agitation following dilution by an aqueous phase. For lipophilic drugs, which have dissolution rate-limited absorption, SEDDS may be a promising strategy to improve the rate and extent ... Delivery Systems…
Lactose monohydrate in the core and different types of Eudragit in the coating. The dissolution experiments involved flat tablets (10 mm diameter, 200 mg weight), the drug release from which
develop and evaluate diclofenac sodium compression coated tablets using different types of Eudragit®.The dissolution experiments involved tablets that were comprised of Diclofenac Sodium, Lactose monohydrate (core) and…
into the extruder and liquefied inside the barrel of the extruder. The in-vitro dissolution studies of the formulations were carried out in pH 7.2 buffer using USP Apparatus
polyvinylpyrrolidone, lactose, magnesium stearate. The controlled release studies were conducted in two aqueous dissolution media at pH 1.2 and 7.4. The dissolution experiments were carried out in a USP XXIII…
Allen’s Device for Kidney Care has been successfully used for the natural dissolution of kidney stones. Dr Allen’s Device that provides Thermobalancing therapy is a class 1 medical
cathodic polarization curves, and the values of the effective activation energy of the dissolution process of alloys, indicating a diffusion control of the process were determined. It is shown that
layer with the maximum value of cubic phase, ZrN, exhibits the greatest anodic dissolution inhibition in 5% NaOH; two interleaved layers with the maximum value of cubic phases
mechanism of this transformation is discussed The next step of microstructure evolution is diffusional dissolution of θ'' precipitates in the presence of more stable θ' and Ω phases. The maximum
extractability, solubility, and bioavailability of mercury sulfide in alright Ridge soils. Dynamics of the dissolution of mercury sulfide with the aid of various extractants, such as acids and a chelating ... nitric…
which represents several constrains for its performance. In vitro testing namely solubility, permeability and dissolution evaluation represents an efficient widely accepted avenue for pharmaceutical products…
obesity, anti-inflammatory and anti-microbial properties. However, quercetin is predisposed with a poor dissolution rate that resulted in low and inconsistent oral bioavailability. Nanosizing, i.e. reduction of the…
agro residue in India that can be exploited for bioethanol generation. For an efficient dissolution of the biomass and its successive hydrolysis into fermentable sugars requires an efficient pretreatment strategy
time were investigated by dissolving bromine epoxy resin. Experimental results showed that the dissolution rate of the bromine epoxy resin increased with respect to various parameters studied. The optimum condition
process was observed to fluctuate within acidic range (4.05 to 4.83) that aided the dissolution of minerals and fibrillation of chitin nanowhiskers. The high quality of CNW prepared
probably be as a result of corrosion from pipes used in water distribution or dissolution arising from high fabrication activities with in and around the study area. None ... samples plotted within the Na+ - K+ - Cl- -…
For authors and organisers
Publish, present and keep up with your field
Find the right journal for your paper and submit your manuscript.