chromatography (HPLC) coupled with a photodiode array detector; method was developed for the quantitative determination of related substances in API. Chromatographic separation was achieved on Hypersil ... were less…
novel gradient reversed-phase High performance liquid chromatographic method has been developed for quantitative determination sulfide impurity of esomeprazole. The method display quantification potential related…
liquid chromatography (HPLC) method has been developed and validated to simultaneous determination of albendazole metabolites: albendazole sulphoxide (ABZSO) and albendazole sulphone (ABZSO2) in plasma. The…
isocratic, reversed phase liquid chromatographic method was developed for the simultaneous quantitative determination of amlodipine and perindopril in bulk and combined dosage form. The chromatographic separation was…
simple, rapid and precise reversed-phase liquid chromatographic method is developed for simultaneous determination of Flunarizine dihydrochloride, Domperidone and Paracetamol in combined pharmaceutical dosage form. This…
high performance liquid chromatographic method for determination of Ethionamide (ETH) in human plasma was developed. The method involved deproteinisation of the sample with perchloric acid and analysis of the supernatant
diode array detector coupled with electrospray ionization mass spectrometry (HPLC-DAD-ESI-MS/MS) method was established for simultaneous identification of flavonoids and other constituents in the rhizomes of three…
Ritonavir was originally developed as an inhibitor of HIV protease. It is one of the most complex inhibitors. It is now rarely used for its own antiviral activity, but remains ... CYP3A4, so a low dose can be used to…
present paper describes a simple gradient reverse phase Chromatographic method for the quantification of organic impurities in Milnacipran (MCP). Detection ,estimation and good quality resolution was achieved between…
Purpose: To develop a simple, highly sensitive, precise and accurate high-performance liquid chromatographic method with photodiode array detection and validated for the rapid quantification of metaxalone in rat plasma…
simple, sensitive, precise, accurate and specific high performance thin layer chromatographic (HPTLC) method has been developed and validated for estimation of risperidone in solid dosage form. The stationary phase used
rapid, precise and sensitive reverse phase high performance liquid chromatographic (RP‐HPLC) method has been developed and validated for the estimation of Escitalopram and Etizolam simultaneously in combined dosage form
performance liquid chromatography method was developed and validated for the simultaneous estimation of Clindamycin (CDM) and Miconazole (MCZ) present in tablet dosage forms. Method: Chromatographic separation achieved…
from bulk and tablet dosage form has been described in this study. The chromatographic technique was developed using a C18 column and a mobile phase consisting of phosphate buffer ... acetonitrile in ratio 60:40 and at…
simple, precise, accurate, rapid and reproducible reverse phase high performance liquid chromatographic (RPHPLC) method was developed and validated for simultaneous estimation of Ofloxacin and Nitazoxanide…
simple, fast, precise, specific, accurate reversed phase ultra performance liquid chromatographic (UPLC) method was developed and validated for the simultaneous determination of Mefenamic acid (MA) and paracetamol (PC)…
This study was designed to develop and validate a liquid chromatographic method for determination of Embelin in crude extract of Embelia ribes. The chromatographic separation was performed on a HPLC ... using chloroform…
simple, accurate, precise and highly selective reverse phase high performance liquid chromatographic (RP-HPLC) method was developed and validated for Pregabalin and Tapentadol. Chromatographic separation was achieved…
validation of analytical methods varies depending on the application area, the concentration of the analyte, the intention of the study and the nature of the method. Purpose: The present study ... fulfilling…
practices. The aim of this study is the investigation of analytical and chromatographic parameters and conditions to develop HPLC chirality test for simultaneously determination of enantiomeric forms of Citalopram…
phase high performance liquid chromatography (RP-HPLC) method have been developed for the determination of synthesized product of pyrazoline derivative. The chromatographic separation was achieved using HPLC column…
simple, precise, specific and accurate high performance thin layer chromatographic method has been developed for the simultaneous determination of olmesartan medoxomil and indapamide in pharmaceutical dosage form. The…
with the other instrumental methods. The principle of operation also is so simple that parascientific personnel can also operate. The main principle involved in this method is the biochemical reaction ... Paper and thin…