assay. The samples were eluted in an isocratic method using an inertsil ODS column (4.6 mm × 250 mm with a particle size of 5 μ) with a mobile phase consisting
Separation was achieved on a Phenomenex Luna C-18 (250 × 4.6 mm, 5 μm) column, with water: acetonitrile: 2-propanol (66:20:14, v/v/v) as mobile phase, flow
estimation of Lincomycin in tablet dosage form. An Inertsil ODS C-18, 5µm column having 250 x 4.6mm internal diameter in isocratic mode with mobile phase containing methanol: Acetonitrile
cefepime and tazobactam in injectable dosage form. Isocratic separation was achieved on YMC C18 column (250 × 4.6 mm, particle size 5 μm) using a mobile phase consisting of methanol-phosphate
carried out on a liquid chromatograph with a diode array detector using the chromatographic column with the size of 150 × 4.6 mm filled with octadecylsilyl silica gel for chromatography ... phases of 0.1% solutions of…
components separated by using Zorbax SB Phenyl (150 × 4.6 mm i.d × 5 μm) column with UV detection at 210 nm. The mobile phase solvent A and B in the ratio
revealed 5-6 constituents for each extract. The extracts were each washed in a column packed with alumina using n-butanol-glacial acetic acid-water (5:1:4) upper layer
effluents or pharmaceutical industry washouts. The separation was achieved on C18 symmetry C-18 column (250 × 4.6 mm i.d., 5.0 μm) using sodium dihydrogen phosphate with SDS as ion pair
pharmaceutical dosage has been developed. The Separation was carried out on Zorbax SB C18 column (250 × 4.6 mm, 5 μm) column using buffer 6.8 g of potassium dihydrogen orthophosphate
bark F. racemosa, and obtained 68 g of extract concentrated, then separated by gravity column to obtained 4 groups of fraction (A, B, C and D). Separation of the group
crude enzyme was purified by various steps such as ammonium sulphate precipitation, dialysis and column chromatography resulting in partially purified enzyme. The crude, partially purified and standard enzyme were…
buffer solutions were used on Inertsil ODS C18 (150 mm × 4.6 mm, 5 μ) column. The OPA Buffer: Acetonitrile buffer mixture of 53:47% v/v was a selected method
chromatographic separation was performed on Acquity UPLC HSS-T3 (2.1 × 100 mm), 1.8 μ column using gradient elution of 0.1% perchloric acid in water adjusted the pH 2.6 with diluted
developed and validated by using Acquity UPLC HSS C18, 1.8 (100 × 2.1 mm) column with oven temperature maintaining at 40°C. 0.01 M Phosphate buffer pH 2.5 and acetonitrile were
drugs were analyzed with the aid of Inertsil C18 (250 × 4.6 mm, 5 μ) column using the combination of 0.1 M disodium hydrogen phosphate buffer: acetonitrile: methanol in the ratio
comaric acid, p-hydroxy benzoic acid and gallic acid) were isolated and identified by column chromatography. In conclusion, Nannochloropsis oculata algal extract showed scavenging activities against oxidative stress…
hexane extract as much as 35 g, separated by gravity column and obtained four groups of fractions, namely the fraction A, B, C and D. Group fraction A, that
developed for the accurate and precise determination of Valganciclovir using Phenomenex Gemini-NX C18 Column (250 mm Length × 4.6 mm diameter × 5 μm particle size) and variable wavelength (UV) detector
eluent consisting of n-hexane:2-propanol (100:2 v/v) and flowing through column at rate of 1.0 ml/min. The column effluent was examined by using UV detector
mixtures and dosage forms. The developed method performed on a Hypersil® C18 reversed phase column (250 mm × 4.6 mm, particle size 5 μm) using a mobile phase consisting of acetonitrile
mobile phase at a flow rate of 1.5 ml/min over Intersil ODS C18 column (250 mm × 4.6 mm × 5 μ). The UV detection wavelength was fixed ... column temperature being maintained at ambient temperature. The method shown good…
rapid and economic. The Chromatographic separation was achieved isocratically on a C- 18 column by utilizing di-ammonium hydrogen phosphate buffer: ACN: MeOH
For authors and organisers
Publish, present and keep up with your field
Find the right journal for your paper and submit your manuscript.