hydroxyl amine under alkaline conditions and exhibiting λ max at 720 nm. The Regression analysis of Beer’s Law plot showed good correlation in a general concentration range ... correlation coefficient (r= 0.999). The…
linearity, accuracy, precision, ruggedness, robustness and solution stability. The response of the drug was linear in the concentration range of 20-120 μg/mL. Limit of detection and limit ... within the limits of…
present work describes HPTLC method for analysis of Nadifloxacin and Mometasone furoate in topical cream. The separation was carried out on Merck precoated silica gel aluminium plate 60 F254 using ... densitometric…
high-performance liquid chromatographic method has been developed for the simultaneous analysis of Losartan potassium, Amlodipine besilate and Hydrochlorthiazide in combined solid dosage form. The mobile phase…
using instrumental response at selected wavelength and concentrations of analyte in the solution. Linearity for the detector response was observed in the concentration range ... methods were validated as per ICH…
high performance thin-layer chromatographic (HPTLC) method was developed and validated for the quantitative analysis of ciprofloxacin hydrochloride. The stationary phase employed was precoated silica gel 60F254 HPTLC…
accuracy, specificity, robustness and ruggedness, in accordance with ICH guidelines. The calibration curve was linear in the concentration range 360-840ng perband for cefixime trihydrate ... proved to be a rapid and…
obtained with 2D-QSAR study using stepwise multiple linear regression (MLR), partial least squares regression (PLSR), and partial component regression (PCR) analysis and two statistical significant models were generated
retention times were 2.449 and 4.895 min for Candesartan and Hydrochlorothiazide respectively. Linearity was obtained in the concentration range 50 to 150 μg/mL for Candesartan cilexetil ... Hydrochlorothiazide, with a…
respectively. The results of analysis were validated statistically and by recovery studies. Linearity, accuracy and precision were acceptable in the ranges (20-100 μg/ml) for aspirin
data set into training and test set. Partial least square (PLS) linear regression analysis coupled with stepwise variable selection method was applied to derive QSAR models which were further validated
from the interference of excepients. The results of the tablet analysis were validated with respect to accuracy (recovery), linearity, limit of detection and limit of quantization were found
been carried out by non-isothermal thermogravimetric analysis technique in which sample is subjected to condition of continuous increase in temperature at linear rate. Thermal study of the resin ... single stage by…
methanol. The developed method was validated with respect to linearity, accuracy (recovery), precision and specificity. The optimum conditions for analysis of the drug were established. The drug obeyed the Beer
accurate, precise, rapid, selective and reproducible high performance thin layer chromatographic method for quantitative analysis of atomoxetine hydrochloride as the bulk drug and in pharmaceutical formulations has been…
method was validated for linearity, accuracy, precision and specificity as per ICH norms. The developed and validated method was successfully used for the quantitative analysis of commercially available dosage form…
activity. Physicochemical parameters were calculated using PaDEL descriptor software, version 2.1. Stepwise multiple linear regression analysis was applied to derive QSAR models, which were further evaluated for…
wavelength selected was 250 nm. Retention time of Olmesartan medoxomil was 2.591 min. Linearity of the method was found to be 50-150 μg/ml, with the regression coefficient ... respectively. There was no significant…
optimum value of stirring rate was determined to be 400 rpm. Calibration curve is linear in the range 9.75 10-3 to 3.25 μg L-1 with a detection limit ... relative standard deviation were 0.9999 and 1.62%. The developed…
been carried out by non-isothermal thermogravimetric analysis technique in which sample is subjected to condition of continuous increase in temperature at linear rate. Thermal study of the resin ... single stage by…
reverse phase - high Performance Liquid Chromatographic (RPHPLC) method was developed and validated for the analysis of Lopinavir in bulk drug. Chromatographic separation achieved isocratically on a C18 column (Use…
required resolution, accuracy and precision thus enabling the utility of the method for routine analysis. The chromatographic separation was achieved on a Xterra RP-18 column ... peaks are around 3 and 6 minute…
observed in the concentration range of 10- 60μg/ml with correlation coefficent 0.9997. The linear regression equation obtained by least square regression method were y=0.0132X-0.0016, where ... proposed method is…
process was carried out in methanol as the solvent. Linearity for detector response was observed in the concentration range of 5-40μg/mL for Method A, Method ... applied for the determination of Minoxidil in there…
For authors and organisers
Publish, present and keep up with your field
Find the right journal for your paper and submit your manuscript.