viscosity of the gels at 370C due to sol-gel conversion with increase in temperature. The viscosity and mucoadhesiveness increased with increase in C 934. In vitro release studies showed ... rate of drug release…
develop a mucoadhesive in-situ gel; formulation was developed to have a controlled kinetic drug release and to minimize the toxic effects of diltiazem Hydrochloride (DTZ). DTZ was incorporated into ... that as the…
release coating of pharmaceutical dosage forms are governed by several variables such as plasticization, temperature and humidity. For plasticization, special plasticizers are used that weaken the intermolecular…
natural origin; hydrotropic salts not only induce swelling and gelatinisation of starch at reduced temperatures but at fairly high concentrations increase the solubility of poorly soluble drugs in water ... lesser…
design was chosen to study the influence of rate of stirring, polymer concentration and temperature on the drug entrapment and drug release parameters. Better entrapment and drug release was achieved ... possibility of…
included simple sample treatment with sonication of small amount of powder sample at ambient temperature and dilution; short elution time; good precision (RSD less than 2) and high recovery (greater ... counterfeit…
analytical column in isocratic mode at room temperature and UV detection at 245 nm. The compounds were eluted at a flow rate of 1.15 ml min-1. The retention times ... excipients present in formulation and it can be used…
alcohol are hydrophobic excipients used as a rate-controlling membrane to modulate the drug release from dosage forms. Coating conditions (temperature, speed of pan rotation, air pressure, etc.) were investigated…
Acid, Prontosil ODS C18 Column (250 x 4.6 mm and 5μm) kept at room temperature and UV detection at 268nm. The compounds were separated isocratically at a flow rate ... simple, does not require any sample extraction and…
triazine-7,9-dicarbonitrile (CTPTC) in hydrochloric acid has been investigated at various temperatures using electrochemical techniques (impedance spectroscopy (EIS), potentiodynamic polarization). Inhibition efficiency…
wavelength at 240nm respectively and the column temperature was maintained at 35°C. The capability of stability indicating method developed was demonstrated by studying the degradation products generated during ... used…
depends upon factors like temperature modulation, pH changes, presence of ions and ultra-violet irradiation, from which drug gets released in sustained and controlled manner. The objective of this study
uses science and risk management approaches to gainproduct and process understanding and ultimately process control. The concept of QbD canbe extended to analytical methods. A simple Analytical method was developed…
room temperature for 1 month. The developed system has the dual advantages of being gastro-retentive, to increase oral bioavailability and releasing drug in a controlled manner, to reduce frequency
column with mobile phase Orthophosporic acid (pH-2.1): Methanol (40:60v/v) and column temperature 30oC. The flow rate of the mobile phase was adjusted ... Montelukast sodium in tablet formulation. Hence this method can…
column, (250 mm × 4.6 mm i.d., particle size 5 μm) maintained at ambient temperature and mobile phase composed of a mixture of 10 mM Phosphate Buffer (pH- 3) Acetonitrile ... methods proved to be specific, robust and…
HPLC method utilizes Shisheido C18, 250mm x 4.6mm, 5μm column (at ambient temperature), isocratic run (using methanol and acetonitrile as mobile phase), at a flow rate ... proposed method can be used for routine…
prolonged release of entrapped metronidazole and voriconazole compared to control gel. Stability studies showed that the vesicles were stable inrefrigerated temperature (4 °C) for 60 days without significant differences
employed on symmetry Shimadzu LC-20 ATVP Kromasil C-18 column Column at ambient temperature. The mobile phase consisted of Methanol : Orthophosphoric acid(1%) : Acetonitrile ... validated as per the ICH guidelines. The…
during storage in low temperature (40 ± 20C), room temperature (290 ± 20C) and high temperature (400 ± 20C). The results of the stability test showed that all formulas no change occurred ... include Streptococcus…
particle size (Make: Dikma technologies) column kept at temperature of 400C, and the components were separated by introducing mixture of 0.1% orthophosphoric acid buffer of pH 5.5, methanol and acetonitrile ... analysis…
hand, are for all time associated with chemical and physical climatic factors, such as temperature or moisture extremes, farming factors such as nutrient deficiencies, mineral toxicities and pollution ... severity of…
adaptation and tolerance of plants. Dehydrins are proteins that affected by water stress, low temperature, salinity and abscisic acid (ABA) and they accumulate in vegetative organs, which suggests a protective…
Acetonitrile (80:20v/v) at a flow rate of 1.1 mL/min. The column temperature was maintained at 30°C and the detection was carried out using a PDA detector ... fast, accurate, precise and sensitive hence it can be…
For authors and organisers
Publish, present and keep up with your field
Find the right journal for your paper and submit your manuscript.