concentration range of 0.28 – 7.26 μg /ml with correlation coefficient 0.998. The linear regression equation obtained by least square regression method were y = 0.094 x + 0.152, where ... proposed method is precise and…
mobile phase showed the most favorable chromatographic parameter for analysis. The detection of the constituent was done using UV detector at 248 nm. The retention time of valsartan was found ... minutes. The method was…
method was found linear over the concentration ranges of 160–240 μg/ml (R2 = 0.9993). The proposed economic method could be applicable for routine quality control analysis
wavelength of 210nm with a flow rate of 1.2ml/min. The linear regression analysis data for the calibration curve showed a good linear relationship with a regression coefficient ... linear regression equation was y =…
measured at selected wavelengths (257.2 nm for Hydrochlorothiazide and 271.6 nm for Olmesartan medoxomil). Linearity was observed in the concentration range ... respectively. The proposed methods have been applied…
Linear Optical single crystals of Urea L-Malic acid(ULMA) were grown successfully by slow evaporation technique. Crystalline natures of the grown crystals were confirmed by Powder XRD analysis. Doping
Olmesartan medoxomil in drug as well as in tablet dosage form. The HPLC analysis used a reversed phase Kromasil C18 (150 x 4.6mm, 5μm) column and a mobile phase ... impurity determination of olmesartan in the dosage…
Proguanil hydrochloride in drug as well as in tablet dosage form. The HPLC analysis used a reversed phase Kromasil C18 (150 x 4.6mm, 5μm) column and mobile phase constituted ... proguanil hydrochloride in dosage as well…
developed method was validated with respect to linearity, accuracy (recovery), precision and specificity. The optimum conditions for analysis of the drug were established. The drug obeyed the Beer
Metoprolol Tartrate and Chlorthalidone in tablet dosage form is developed and validated. The chromatographic analysis was performed on a C 18column grace smart RP18 ... lamivudine and stavudine were found to be 2.50 min…
reverse phase high performance liquid chromatography method was developed and validated for the quantitative analysis of Vemurafenib in bulk drug and dosage form using C8 column(150x ... with a flow rate of 1.0ml/min…
wavelength range 2 15-230nm was selected for estimation of Desvenlafaxine succin ate. Linearity was observed in the concentration range 10-50µg/ml for both the methods ... simple, precise and accurate and can be…
point of Pioglitazone) for Glimepiride. Pioglitazone HCl (R2=0.9912) and Glimepiride (R2=0.9964) shows Linearity in a concentration range of 5-30μg /ml and 4-20μg/ml respectively ... found to be 0.056μg/mL and 0.40…
flow rate of 1 ml/min and UV detection at 292 nm. The linearity of the proposed method was investigated in the range ... respectively. This procedure was found to be convenient and reproducible for analysis of these…
oxidative degradation product were linear in the range 4–24 mg/mL with correlation coefficients not less than 0.9996. The proposed methods were applied for analysis of laboratory-prepared mixtures
HPLC). The calibration curve was found to be linear with the equations of y = 0.0445x + 0.006 and y = 57694x - 10767 with correlation coefficients of 0.9996 and 0.9994 (r2) over ... with a low LOD and LOQ. The method…
respectively. Quantitation was achieved with PDA detection at 217 nm. The linearity of BRO and CIP was in the range ... economical in terms of the time taken and amount of solvent consumed for each analysis. The method…
Method I and 6.4min and 7.4min for Method II.Good linearity was demonstrated in the range of 5-250 μg/ml and 10-240 μg/ml for Rosiglitazone ... statistical correlation has been shown and can be applied for routine…
difference (peak-to-trough) amplitudes between two selected wavelengths in the ratio spectra. For analysis of HCT/CRV mixture, 20 μg/mL CRV was used as a divisor ... between 269.5 and 287.5 nm were found proportional to…
respectively. The method was validated as per the ICH guidelines for linearity, limit of detection, limit of quantification, accuracy, precision, robustness and solution stability. Stability indicating capability of the…
controls group. Statistical analysis performed using SPSS program (version 18, Chicago, IL, USA). Kaplan Meier, T-test and log linear tests used to compare variables between cases and controls
retention time of trimetazidine was found to be 3.8 min. The linear regression analysis data for the calibration plots showed good linear relationship within the concentration range