devised method involved separation of Pramipexole (PRM) on a Reversed Phase Waters Symmetry Column and determination with UV detection at 260 nm. The standard curve was linear (R = 0.999) over
150mm, 5μm Symmetry shield RP 18 column with the isocratic mobile phase of 0.02M aqueous potassium dihydrogen phosphate buffer (pH 7.5) and acetonitrile
kept 10-15 0 C below the upper temperature limit. The amount of column bleed (vaporization of the stationary liquid phase) must be minimized to prolong the column life ... knowledge of molecular interactions. Currently…
reverse phase HPLC analysis was done on a Merck C18 4.0 mm× 250 mm, column with mobile phase consisting of 0.1%phosphoric acid(pH adjusted to 2.5 with triethylamine) - acetonitrile
carried out on a Phenomenex – Luna, C18 (250 x 4.6 mm i.d.,5μ) column. using filtered and degassed mixture of acetonitrile ,water and methanol (55:40:5) as mobile phase
simultaneous estimation of Drotaverine and Mefanamic acid in tablet dosage form using C18 column(LC 20 AT Isocratic) in Isocratic mode. The mobile phase consisted of Acetonitrile, methanol
evaluate different factor affecting Drug-Resin Complexation wise, effect of batch and column process, complexation time, temperature, and pH on Fexofenadin Hydrochloride loading on Doshion P547 is reported. Drug resin
online coupling of extraction with cyclone P (50mm x 0.5mm, 50μm) HTLC column by injecting 15μL sample and chromatographic separation is performed with C18 Reverse phase column using
determination of Pioglitazone Hydrochloride. Separation was achieved with an Symmetry - Extend - C18 HPLC column 150mm in length and having an internal diameter of 4.6mm. A mobile phase comprising
tablet dosage form. Chromatographic separation of the drugs was achieved on a Eurosphere C18 column (5 μm, 250 mm × 4.6 mm, i.d.) with the isocratic mobile phase methanol: sodium acetate
reverse phase Zorbax SB C18, (250 x 4.6 mm, 5 mm) analytical column. Mobile phase contains methanol, acetonitrile and 50 mM sodium dihydrogen orthophosphate
pharmaceutical dosage forms. Chromatographic separation was achieved on an Octa Decyl Silyl column (C-18, 250 mm x 4.6 mm, 5 μm particle) with a 20:80 (v/v) mixture
validated. The separation was achieved on Luna C18, 5μm 4.6 mm×250 mm column, using mobile phase composition of buffer (pH 4.5): Acetonitrile: methanol (45:25:35), at a flow
protein binding of Ibuprofen in Bovine serum albumin. A Phenomenex C 18 Gemini column (150×4.6 mm), 5 μ particle size was used as stationary phase and Mobile phase contained
been developed and validated. Best separation was achieved on a Thermo Hypersil C4 column (25 cm X 4.6 mm, 5 μm) using a mobile phase of 0.01 M ammonium acetate
achieved in gradient mode using Kromasil 100, C18, 30 x 3.0 mm, 3.5 μm column with mobile phase A containing 0.5% Triethylamine buffer (pH adjusted to 4.8±0.05 with Orthophosphoric
simultaneous estimation of Olmesartan medoxomil and Hydrochlorthiazide acid in tablet dosage form using C18 column (LC 20 AT Isocratic) in Isocratic mode. The mobile phase consisted of Acetonitrile, methanol
Doxophylline (DOX) present in tablet dosage forms. Chromatographic separation achieved isocratically on Luna C18 column (5 μm, 150mm x 4.60mm) and Acetonitrile/KH2PO4 buffer
Atenolol Related substance in pure drug. The quantification was carried out using stainless steel column C18 125 mm x 4.0 mm, 5 μm BDS Hypersil in Isocratic mode with mobile
standard solution, and record the peak responses as directed under procedure: the column efficiency is not less than 6000 theoretical plates, the tailing factor Gabapentin is not more than
Atorvastatin and Atenolol in tablets. The compounds were separated on an ODS analytical column with a mixture of Acetonitrile, and Phosphate buffer (pH 4.5±0.05 adjusted with ortho phosphoric acid
been validated for determination of related substance in Trazodone hydrochloride using C8 ODS (150X4.6mm) column by keeping the flow rate of 1ml/min and having sensitivity of 1.The elution
Domperidone (DOM) and Pantoprazole(PAN) in capsules. The drugs were separated on an analytical column, HiQ Sil C18V, 4.6mm x 250 mm, 5 μm (Kya Tech Japan). The mobile
degradation products, using an Ace5-C18 (250×4.6 mm, 5 μm) advance chromatography column, and 10 mmol L-1 methanol and water (70:30 v/v) as a mobile phase