Development and validation of RP-HPLC method for nifedipine and its application for a novel proniosomal formulation analysis and dissolution study
The aim of the present study was to develop and validate a
Articles, journals and conferences in one search. An exact title, DOI or ISSN is listed first.
In the search box: "exact phrase" · -leave out · OR · prefix* · title: author: journal:
The aim of the present study was to develop and validate a
Hydroxide. The standard and sample was scanned and the absorbance is scanned at 245.3 Linearity was observed in the concentration range from 20-45 μg/ml with a correlation coefficient ... pharmaceutical tablet…
Two simple, precise and economical UV spectrophotometric methods have been developed for
validation parameters were within the acceptable limits. The results of rilpivirine were determined by linear regression equation with slope; 0.0047, intercept; 0.00066 and correlation coefficient of 0.9998. The…
proposed method is validated with respect to accuracy, precision, linearity and limit of detection. The suggested procedure is successfully applied to the determination of the durg in pharmaceutical preparation, with…
methods. Structures of synthesized compounds were confirmed by IR, 1H-NMR, mass and elemental analysis. Compounds were further evaluated for analgesic and anti-inflammatory activity by in vivo models ... dimensional…
oxidizing agent and MBTH and MIG/ALV followed by MBTH and oxidizing agent. The linearity was assessed and found ... methods were proved to be more accurate, simple, precise and rapid by statistical analysis
HCTZ) for the analysis in methanol. Linearity range was observed in the concentration range of 5-30μg/ml for losartan potassium and hydrochlorothiazide. Developed methods were applied to marketed
diagnosis and treatment of cancer. Thus, improvements in cancer classification are increasingly sought. Linear discriminant analysis (LDA) is the most effective method of cancer classification in high-dimensional…
respectively. The proposed method has permitted the quantification of Cefixime in the linearity range of 60 -140 μg/mL and for Ofloxacin in the range ... were found to be 0.16 - 0.49 μg/mL respectively. The validated…
Area Under Curve (AUC) method .For analysis of nelfinavir by AUC method the wavelength range selected was 250nm to 260nm because the linearity was obtained within these area with good ... Method is validated according…
Software. To investigate the relationships between predictor and criterion variables, Pearson correlation and linear regression analysis were used .The mean age of patients was 33/36 and the majority
respectively. The method is accurate (99.2-102.9%), and linear within range 3-15μg/ml and 4-20μg/ml for ciitapride and pantoprazole respectively. The correlation coefficient was found ... respectively. The proposed…
The electrochemical oxidation of mefenamic acid has been investigated by cyclic, linear
symmetry C8 reverse phase column (150×3.9mm, 5μm) dimensions at ambient temperature. The analysis was performed with run time of 18.0 minutes at a flow rate ... quantification limits were 27.0μg/ml and 92.0μg/ml…
This study was aimed to develop stability indicating RP-HPLC method for analysis of Tenofovir. Successful separation of drug from degradation products formed under stress conditions was achieved ... observed at 7.33…
In the present study, the vibrational spectral anal ysis of 2-chloro
structure of the site is available then the results of formal methods using linear multiple regression analysis should be carefully examined to detect and discard any molecule presenting a different
time and applied voltage were optimized.Under the optimal extractions conditions, the method demonstrated good linearity in the range of 0.5-500 μg L-1 withgood correlation of determinationr2 ... were obtained. The…
physical activity with lung function in Hail City, Saudi Arabia. Materials and Methods: This analysis included 359 females aged 18–44 years with no known preexisting serious illness ... Questionnaire” (IPAQ). Results…
In this study, ultratrace level of cyanide was dete cted based on
solid phase through C18 SPE cartridges. The proposed method of phosmet residue analysis by GC/MS uses a capillary type Supelco®, the oven temperature was programmed from ... analyte and EI are 14.34 and 14.67 ± 0.02…
been determined experimentally. The validation characteristics of the proposed method (linearity, accuracy, precision, robustness) have been studied. The estimation of validation characteristics of the quantitative…
molecules composed by 29 atoms was employed for the study. Linear multiple regression analysis was employed to find the relationships between the variation of the values of the biological activity
using portable HemoCueR Hb 301 system. Predictors of anaemia were estimated using multiple linear regression analysis. Results: The mean Hb was 10.8±1.4 g/dl and prevalence of anaemia
For authors and organisers
Find the right journal for your paper and submit your manuscript.