developed and validated after optimization of various chromatographic conditions. A Hiber C18, 5 μm column having 250×4.6 mm i.d., with mobile phase containing 0.05 M potassium dihydrogen phosphate : acetonitrile
Tenofovir Disproxil Fumerate in pharmaceutical dosage forms. Chromatography was carried out on a C18 column [250mm, 4.6m, 5μm] using a mixture of methanol: phosphate Buffer
separation was achieved on Chiralcel OD-H, 250 mm Х 4.6 mm, 5 μm column using a mobile phase system consisting of n-hexane, isopropyl alcohol and trifluoroacetic acid ... ratio of 948:50:2 (v/v/v). The mobile phase was…
hydrophilic interaction chromatography (HILIC) and evaporative light scattering detection (ELSD). Altech Altima HP HILIC column (250 x 4.6 mm, 5μ particles) was used along with the mobile phase consisted
phase K2HPO4 – pH 6.5 : Acetonitrile (68 : 32) with isocratic programming, Hypersil, BDS, C 8, column (150 mm x 4.6 mm i.d., 5μm particle size) as stationary phase with a flow
mobile phase UV detection at 273 nm and Sunfire C-18 column .flow rate 1ml/min. the extraction Recovery of octopamine from its formulation dosage form (tablets
drug was achieved on Symmetry C18 (150mm x 4.6mm i.d., 5mm particle size) column with UV detection at 254 nm and the mobile phase consist of Buffer and Methanol
Forms. Chromatographic separation was achieved on a Kromasil C18 (150×4.6 mm), 5.0 μm column with a 750mL of 0.01M anhydrous dipotassium hydrogen orthophosphate, added 2mL Triethylamine then adjusted
soxhelation was carried out. Marmelosin was separated out from extraction of Aegle marmelos by Column chromatography methods. Marmelosin derivatives were synthesized using Nitration, Sulphonation and Bromination…
used as an internal standard. Zorbax-SB C18, 75 x 4.6 mm, 3.5 μm column provided chromatographic separation of analyte followed by detection with mass spectrometry. The method involves simple
developed. The lignan peak was separated from endogenous peaks on phenomenex ODS 5μ C18 column (250 x 4.6mm) with mobile phase comprising of phosphate buffer: acetonitrile
determination of Nelfinavir Mesylate in tablet dosage form. Chromatography was carried on an ODS column using a mixture of methanol and water (80:20 v/v) instead of Acetonitrile
samples by liquid-liquid extraction technique. The reconstituted samples were chromatographed on a C18 column by using a 90:10, v/v mixture of acetonitrile and 5 mM ammonium acetate
estimation of atropine in Kankasava polyherbal branded formulations. The separation was achieved with a column RP C- 18 (250 mm X 4.6 mm X 5 micron) using mobile phase mixture
extraction (SPE) using Oasis HLB cartridges. The eluted samples were chromatographed on a C18 column by using a 20:80 v/v mixture of ammonium formate buffer
reverse phase chromatography on Shimadzu HPLC, 10-At detector with hypersil ODS C18 Column 250 X 4.6 mm (particle size of 5μ) and constant flow pump. Rheodyne injector with
Chromatographic separation was performed on Xbridge C18, 50 x 4.6 mm, 5 mm column with an isocratic mobile phase composed of 5mM Ammonium formate (pH 9.0) : Acetonitrile
liquid chromatogram is equipped with a 254 nm detector and a 4.6 ´ 25 mm column that contains 5 mm packing L1 (Hypersil BDS C18 4.6´ 250 mm, 5 mm column
reverse phase chromatography on Shimadzu HPLC, 10-At detector with hypersil ODS C18 Column 250 X 4.6 mm (particle size of 5μ) and constant flow pump. Rheodyne injector with
with dilute NaOH, with a flow rate of 0.5mL/min, C-18 column & UV detection at 254nm.The method was validated for linearity, accuracy, ruggedness, robustness, precision & bench top stability
development was carried out on Agilent Eclipse XBD-C18 (5μm, 150mm × 4.6mm I.D.) column. The mobile phase was a mixture of buffer (20mM KH2PO4) and methanol in the ratio
Dexketoprofen trometamol and Paracetamol from tablet dosage form using a Hypersil BDS, C18 column (5μ, 4.5 mm x 250 mm) column and mobile phase composed of 0.01m Potassium Dihydrogen
simulated dosage form. All the drugs were separated on a 250mm×4.6mm C18 column packed with 5 μm particles. The mobile phase, optimized through an experimental design
tablet dosage form. The method development was carried out using Phenomenex, 250x4.6mm, 5μ column and mobile phase of methanol: water (60:40)v/v with the flow rate