Hypersil C18 (150 x 4.6 mm i.d.) with 5 μ particle size column showed most favorable chromatographic pattern over the other columns. The mobile phase consisted of a mixture
separation was achieved on Waters Acquity UPLC BEH C8 , 100x 2.1 mm ,1.7μm column in a gradient mode elution. Detection wavelength was set at 270 nm. Drug product
impurities and its degradation products in pharmaceuticals preparation. HPLC was performed on a C18 column with “mobile phase A” consisting of 95:5 v/v of pH 2.5 buffer solution
methodology was achieved on C18 (typically 75mm length, 4.6mm ID and 3.5μm) column with optimized conditionsof Mobile phase 0.1% Orthophosphoric acid (pH-2.1): Acetonitrile: Methanol ... Column temperature, sampling…
Olmesartan Medoximil, Metaprolol Tartarate in bulk drug and pharmaceutical dosage forms. A Xterra C18 column having 150 mm x 4.6 mm, 5 μm in isocratic mode, with mobile phase containing
Acetonitrile, Methanol and Orthophosphoric acid in the ratio of 300:200:400:1. The column used for separation was Hypersil BDS, C18 (4.6 x 250mm x 5μ) with flow rate
acetonitrile mixed by a low pressure gradient program. Hypersil BDS C18 column was used. The wavelength detection was set at 205 nm. Linearity range for tolterodine
human plasma was developed and validated. Rabeprazole was resolved on a reverse phase C18 column from the endogenous plasma components by isocratic elution of 30% 25mM phosphate buffer
detection for determination of hydrogen cyanamide residues. The evaluated parameters include the type of column (CHEM ELUTTM), the nature of eluent (hexane, ethyl acetate, methanol and water) and procedure
dosage forms. Chromatographic separation was achieved isocratically on a Thermo Scientific Hypersil BDS C18 column (150 mm x 4.6 mm I.D., 5 μm particle size) utilizing a mobile phase
method was standardized for nebivolol using Shimadzu HPLC model reverse phase analytical Inspire C18 column (250 mm x 4.5 mm, 5 μm particle size) with LC10AD Pump
performed on ACE C18 (250 x 4.6 mm; 5 μm particle size) analytical column as the stationary phase. The solvent system consisted of Water and methanol in the ratio ... with potassium dihydrogen phosphate as mobile phase…
keeping with the ICH pointers. For this purpose ODS C18 (4.6 x 150mm, 5mm) column was used. As a mobile part, a combination of Phosphate buffer, Acetonitrile and Water with
Imatinib Mesylate in pure and pharmaceutical formulation. The separation was achieved on C18 G column ( 250 x 4.6 mm i.d, 5 μm), using o-Phosphoric acid (0.1% v/v): Acetonitrile
sodium(MKT) in bulk and pharmaceutical formulation. The RPHPLC was performed on YMC C18 column (250, 4.6I’d, 5μm particle size) column with mobile phase Orthophosporic acid ... Methanol (40:60v/v) and column temperature…
tablet dosage form. An isocratic RP-HPLC was performed by utilizing Welchrom C18 column, (250 mm × 4.6 mm i.d., particle size 5 μm) maintained at ambient temperature and mobile phase
Column chromatographic separation of the methanol extract from the Saccopatlumhorsfieldii Benn’sstem bark yielded four phenolic components including three flavonoids, kaempferol-3,4’-dimethylether(1), quercetin-3,7-…
Zorbax Eclipse C18 (250 x 4.6 mm i.d.) with 5 μ particle size column showed most favorable chromatographic pattern over the other columns. The mobile phase consisted of a mixture
maleate in combined tablet dosage form. Isocratic chromatography was performed on a Symmetry C18 column (150X4.6mm, 5mm, XTerra) with a mobile phase consist of 70:30v/v Methanol : Phosphate buffer
bulk and pharmaceutical Dosage Forms. Seperation was achieved on Chromosil C18 (250×4.6mm)column with Methanol: Acetonitrile 75:25 v/v as a mobile phase at a flow rate
Prominence Liquid Chromatography SPD 20-A Shimadzu Japan. The UV-VIS detector and C18 column with dimension on 250×4.6 mm was used at wavelength 234 nm. Finally Nimodipine impurity
developed for the simultaneous determination Paracetamol and Tapentadol HCl in pharmaceutical dosage form. The column used was Hyperchrome C18 (250mm x 4.6, 5μm) in isocratic mode, with mobile phase containing
Chromatography was carried out on Altima C18 (150 x 4.6 mm, 5m particle size) column in an isocratic mode with mobile phase containing phosphate buffer (adjusted to pH 4.8 with
phospholipid free filtrate obtained through Hybrid SPE-Phospholipid cartridge was chromatographed onto Gemini C18 column (75 x 4.6 mm, 3.0 μm). An isocratic mobile phase of a mixture of 10mM ... using this new Hybrid…