olive flounder. Separation was carried out on an Eclipse Plus C18 column by gradient elution using wateracetonitrile with 0.1% formic acid at a flow rate
particle size) at flow rate 1.5 mL/min. with 270 nm detection through gradient elution. Mobile phase-A (MP-A) consists of Water : Acetic acid (980:20) and Mobile phase
types of organic phases including acetonitrile, methanol and the acetonitrile/methanol cocktail under a gradient elution system have been particularly compared for metabonomic analysis. The results showed that the number
determined by HPLC with Sunfire C18 ODS column (4.6 × 250 mm, 5 µm) by gradient elution using acetonitrile (A) and 0.8% acetic acid (B) as the mobile phase. The flow
Waters ACQUITY UPLC BEH C18 (2.1 mm × 50 mm, 1.7 μm) column using a gradient elution with 0.1% (v/v) formic acid/water and acetonitrile as mobile phase
performed on a Waters HILIC column (100 mm × 1.7 mm, 2.1 µm) with gradient elution using 0.1% formic acid aqueous solution (A) and acetonitrile (B) at a flow rate
gliclazide (GLZ), glibenclamide (GLB) and repaglinide (RPG). The chromatographic separation carried out using gradient elution mode with acetonitrile: 0.05M potassium dihydrogen phosphate (MKP) and 0.01M sodium octane…
flight mass spectrometry (LC/ToF) to identify these compounds. Separation was performed via a gradient elution of acidified water and acetonitrile mobile phases on a C18 stationary phase held
benzene resin based SAX column (with covalent bonded trimethylammonium anion exchange groups); a linear gradient elution from 10% to 41% of solution-B, which is 0.5 M lithium perchlorate containing
achieved using ACE 5 C8, (50 mm x 4.6 mm, 5µm) column with gradient elution mobile phase of 0.25 mM Ammonium chloride and methanol. The method validation intends to investigate
Water: Acetonitrile (pH of water was adjusted to 3.0 with Orthophosphoric acid) through gradient elution. Product was subjected to stress conditions like acid, base, peroxide, thermal and photolytic degradation
separation of all polyphenols was performed on a BEH C18 column using a linear gradient elution with a binary mobile phase mixture of aqueous 0.1% formic acid and methanol
using 0.02% trifluroacetic acid and acetonitrile as mobile phase with gradient elution. The flow rate was 1.0 mL/min and quantification was carried out using ultraviolet detection at wavelength
method for the determination of these analytes was developed, using a gradient elution with a binary mobile phase, the analytes being revealed by means of an ESI-QqQ Mass Spectrometer
ACE3, C8, 100x4.6mm, 3μ analytical column at 35°C employing a gradient elution. Mobile phase consisting of Solution–A (20mM Ammonium acetate buffer of pH 5.5+ 0.05) and Solution
achieved on shim-pack XR-ODS II (3.0 × 100 mm, 2.2 μm), and the gradient eluted within a period of time, that is, 15 minutes. The eluted compounds were monitored
Inertsil C8 (250 X 4.6 mm 5 µ particle size) column using gradient elution at PDA detector. The optimized mobile phase consisted of 0.1 % Trifluoroacetic acid as a mobile phase
formic acid-methanol solution were used as the mobile phases with the optimum gradient elution procedures. Multiple-reaction monitoring (MRM) mode was applied for qualitative and quantitative analysis, and matrix
consisted of ammonium formate (pH 4.5) and methanol (10:90 v/v) in non-gradient elution mode. Our results demonstrated that both ionization sources showed matrix effect
following conditions: a reverse phase C18 column maintained at 25°C with a gradient elution program using acetic acid 0.2% and methanol as mobile phase pumped
detection. The chromatographic separation was performed on a SinoChrom ODS-BP C18 column with gradient elution using acetonitrile and 0.1% acetic acid-0.5% potassium dihydrogen phosphate aqueous solution