triethyl amine) and acetonitrile was used as mobile phase. The analyte was monitored with UV detector at 275 nm. Typical retention time for prulifloxacin was found
after addition of 5.0 mL of triethylamine) as a mobile phase. The analyte was monitored with UV detector at 228 nm. Typical retention time for donepezil hydrochloride was found
method. Essential oils and fatty acids were measured using solid phase microextraction (SPME) and gas chromatography – flame ionization detector (GC-FID) as described in da Silva and Câmera ... Profiling of volatiles in…
Perindopril and Trandolapril. A rapid, economical, simple, sensitive and reliable stability-indicating reverse phase HPLC method developed and validated for the quantitative determination of all isomers related to…
Northeastern region in India has been performed using a reversed-phase high-performance liquid chromatography with photodiode array detector. The chromatographic separation was carried out on Acclaim C 18 column…
mobile phase at a flow rate of 1.2 mL/min with detection at 285 nm by ultraviolet detector i.e. incorporated in HPLC. The retention time of the drug was found
using Cosmosil C18 column (250 mm × 4.6 mm i.d, 5 µm) and mobile phase consisting of buffer (Mono basic potassium dihydrogen orthophosphate with 10% orthophosphoric acid, pH adjusted ... with the flow rate of 1.0…
using Cosmosil C18 column (250 mm × 4.6 mm i.d, 5 μm) and mobile phase consisting of buffer (Mono basic potassium dihydrogen orthophosphate with 10% orthophosphoric acid, pH adjusted ... with the flow rate of 1.0…
examined oxyHb LFOs at bed-side as a marker of CA in the subacute phase in stroke patients with or without recombinant tissue plasminogen activator thrombolytic therapy. Methods: We recruited ... each side of the head…
were characterized by high-performance liquid chromatography with a diode-array detector HPLC-DAD, Head Space-Solid Phase Micro Extraction followed by Gas Chromatography coupled with Mass Spectrometry (HS-SPME
particle size) and a detector UV-VWD was employed. The mobile phase of 0.05 M disodium hydrogen phosphate and acetonitrile (65:35 v/v) containing 0.5 mL/L triethylamine
common agricultural produces. Equivalent to USP G-42 GC stationary phase, DB-35 ms capillary column and ECD detector was selected on the basis of physical and structural characteristics
guideline in pharmaceutical dosage from use ultra violet (UV) detector. Elution was carried out using a mobile phase consisting of Methanol, Acetonitrile and Ammonium acetate buffer of which
Acetonitrile and Methanol (50:30:20) as a mobile phase. The drug was quantified by a UV detector at 260nm.The method is linear in range of 48μg/ ml to 112μg
estimation of Fingolimod in pharmaceutical dosage forms, using UV detector. Elution was carried out using a mobile phase consisting of Buffer : Water (60 : 40) and flow rate
reversed phase column and Perkin Elmer LC-90 UV detector. Both obeyed first order reaction kinetics, usually following the Lagmuir-Hinshelwood model. A respirometric biosensor was employed to assess
Chromatographic analysis by the HPLC technique with Diode Array Detector was employed for MDMA determination. A mobile phase of methanol/water (90:10v/v) allowed a peak signal for MDMA
butyl ammoniumhydrogen sulphate 70:30 v/v as a mobile phase. The detection was carried out using UV detector set at 320nm. Clonazepamwas used as internal standard. Beer
reverse phase Hibar®C18 (250×4.6 mm i.d., 5 μ) column with the mobile phase consisted of acetonitrile: pottasium dihydrogen ortho phosphate (pH 3.5) in the ratio ... standard (fluticasone propionate). The analyte was…
Shimadzu LC-20AT prominence liquid chromatograph. The mobile phase used is phosphate buffer (pH-3.2): acetonitrile (60 : 40 v/v) with a flow rate of 1 mL/min. The responses ... measured at 285 nm using Shimadzu SPD-20A…
column temperature at30°C and detector wavelength of 215nm. Both the drugs were well resolved on the stationary phase and the retention times were around 10.3 minute for Metoprolol succinate
For authors and organisers
Publish, present and keep up with your field
Find the right journal for your paper and submit your manuscript.