responses were simultaneously optimized by using Derringer’s desirability functions. Optimum conditions chosen for assay were MeCN, MeOH, 20.00 mM K2HPO4 (pH 7.0 ± 0.5) solution ... plasma samples. Total chromatographic…
hydroxyvitamin D-3 [25(OH) VD-3] in human plasma was developed and validated. Plasma samples were deproteinized with a mixture of methanol and 2-proponol, and extracted with hexane ... coefficients of variation for…
washout of one week, plasma was collected at six hours post dosing and assayed by a validated liquid chromatography tandem mass spectrometry method to determine the main pharmacokinetic parameters. Results
valid case definition of leptospirosis. In this case the tests are the microscopic agglutination test (MAT) and an in-house IgM enzyme-linked immunosorbent assay (ELISA) both on single serum ... current laboratory…
simple, sensitive and compatible liquid chromatography tandem mass spectrometric method has been developed and validated for the estimation of Pyrazinamide. Glipizide was used as an internal standard. Detection was…
interaction with its 55 kD receptor (TNFR 1 ). While these therapies have proven the validity of this approach, they are large proteins that require intravenous administration. Small molecule inhibitors ... this…
solvent. Linearity was observed in the concentration range of 4–16 µg/ml. Validation experiments were performed to demonstrate system suitability, specificity, precision, linearity, accuracy, robustness ... neutral…
along with the intact NaCr. The developed methods were validated as per ICH guidelines and were also; suitable for assay determination of the cited drugs in pharmaceutical dosage forms
simple, rapid, precise, and accurate stability-indicating, reversed phase (RP) HPLC assay method was developed and validated for simultaneous estimation of Lamivudine (3TC) and Stavudine (d4T) in bulk drugs
identity of the resulting protein was confirmed by a highly specific enzyme-linked immunosorbent assay. In conclusion, a synthetic G-CSF cDNA in combination with the recombinant DNA protocol offers ... synthesizing the…
5μg/ml with a correlation coefficient of 0.9989. Assay results were in good agreement with label claim. The methods were validated statistically and by recovery studies. The relative standard deviation
Four simple and sensitive extractive spectrophotometric methods have been described for the assay of dicyclomine hydrochloride either in pure form or in pharmaceutical formulations. The developed methods involve…
Three simple and sensitive extractive spectrophotometric methods have been described for the assay of sibutramine hydrochloride either in pure form or in pharmaceutical formulations. The developed methods involve…
erent information compared to existing ones. Th ere is a high interest in identifying, validating and eventually using biomarkers as they may help detecting a disease (e.g.: cancer ... several stringent criteria along…
esoteric type of assays performed on a fi t-for-purpose basis to rigorously validated assays when a biomarker is used as a surrogate end point, for patient selection ... randomization into diff erent arms. Assay…
dormant stage. We had earlier developed an in vitro whole cell based high throughput assay for anti-tubercular screenings. A similar pattern of bacilli dependent conversion of nitrate to nitrite ... count of viable…
Previously recognized antagonists of DC-SIGN/gp120 binding were tested for assay validation to prove that it could detect inhibition. In conclusion, the assay was deemed ready for the high
remain largely unknown. To assess global molecular changes in GAC, we use whole genomic assay to evaluate human GAC samples. Methods: Oligonucleotide array comparative genomic hybridization (aCGH) was performed…
gates. The objective of the study was to develop a simple and sensitive spectrofluorimetric assay method for glutathione transferase using monobromobimane (MBB), a non fluorescent compound with electrophilic site…
detector wavelength (254 nm & 295 nm) for Dorzolamide Hydrochloride & Timolol maleate was developed and validated. The mobile phase consisted of methanol : buffer (60:40), the pH was adjusted ... Dorzolamide…
Simple, accurate and precise spectroflourimetric, spectrophotometric and LC methods have been developed and validated for the determination of irbesartan (IRB). The spectroflourimetric method depends on measuring the…
assay was validated for the parameters like accuracy, precision, robustness and system suitability parameters. The results were found to be satisfactory and the method can be adapted for the routine
forced degradation study was successfully applied for the development of a stability-indicating assay method for simultaneous estimation of Etofylline and Theophylline in a formulation in the presence ... according to…
For authors and organisers
Publish, present and keep up with your field
Find the right journal for your paper and submit your manuscript.