simple, selective, linear, precise and accurate RP-HPLC method was developed and validated for rapid assay of Ascorbic acid in Health drinks. Isocratic elution at a flow rate ... accuracy of the method was found to be…
simple and rapid assay method involving two reaction steps has been developed for assay of ART in pharmaceutical formulations. The method involves basic reaction of ethanolic solution of ART with ... glycal and furanose…
According to Food and Drug Administration (FDA) guidelines, an SIM is defined as a validated analytical procedure that accurately and precisely measures active ingredients (drug substance or drug product) free…
Furthermore our study validates the use of Delicious variety for the treatment of the infections borne by the tested organisms. The pectin extracted was further assayed for cellular toxicity against
rapid HPLC method of roflumilast was validated for parameters specificity, system precision, repeatability, detection limit, quantitation limit, linearity and robustness. High linearity of the analytical procedure was…
presence of common excipients. The percentages assay of Pantoprazole in tablet was more than 99%. The method was validated by determining its sensitivity, accuracy and precision which proves suitability
whole blood and samples were stable for at least the time required to assay the number of samples that could be placed in the auto sampler which is maintaining temperature ... range of 50.285 to 798.179 ng/mL and was…
toxicological studies of nanosystems are growing at exponential rates annually. For these reasons, screening assays are needed to assess the chemical and physical properties of nanomaterials. Lacking the proper…
method was validated in terms of Specificity, Linearity and Range, Precision, Accuracy, Intermediate Precision, Solution Stability and Robustness. The assay was linear over the concentration range of (DMAPIMP
Cefadroxil were found to be 0.77 ± 0.011 and 0.39 ± 0.007, respectively. The method was validated with respect to linearity, accuracy, precision and robustness as per the International Conference on Harmonisation…
effluents were monitored at 265nm and eluted at 4.53 min. The assay was validated for the parameters like accuracy, precision, robustness and system suitability parameters. The proposed method
assay in commercial formulation was found to be in the range 99.01 – 100.90 % for FAM and 98.91 – 101.72 % for DOM by the proposed methods. The methods were validated with respect
Tenofovir disoproxil Fumarate (TNF) and Emitricitabine (EMT) in dosage form was developed and validated as per ICH Guidelines. The separation and quantification were achieved on Agilent C18 column using Methanol…
simultaneous determination of Formoterol fumarate and Fluticasone propionate in Metered Dose Inhaler formulation. The assay involved an isocratic elution of these two component on water spherisorb C8 column…
percent assay for commercial formulation was found to be in the range 98.91%–101.72% for both the analytes by the proposed three methods. Absorption corrected method was successfully applied ... commercial tablet…
high-performance liquid chromatography–diode array detector method (HPLC-DAD) was developed and validated for the determination of tramadol in human saliva. Samples of saliva were prepared utilizing liquid–liquid…
simple and rapid method has been developed and validated for determination of ticlopidine in human plasma using protein precipitation and liquid chromatography coupled with tandem mass spectrometry ... accuracy in the…
short time frame. Objective: A selective and sensitive reverse phase high-performance liquid chromatographic assay has been developed for monitoring of Haloperidol levels. Methodology: Chromatogram separation of…
plasma. The method included liquid chromatography tandem mass spectrometry in negative mode and was validated with nilutamide as an internal standard. Quantitation was performed for the transition ... coefficient of…
respectively. Mean inter-assay accuracy (n=5) ranged from 93 to 101 % and inter-assay precision (n=5) ranged from 3.7 to 9.4% (C.V.). The method was used ... pharmacokinetic studies. This is the first on-line…