SIMULTANEOUS HIGH-PERFORMANCE LIQUID CHROMATOGRAPHIC DETERMINATION OF IRBESARTAN AND HYDROCHLOROTHIAZIDE IN PHARMACEUTICAL DOSAGE FORM
A simple, rapid, accurate and precise method is developed for the quantitative
Articles, journals and conferences in one search. An exact title, DOI or ISSN is listed first.
In the search box: "exact phrase" · -leave out · OR · prefix* · title: author: journal:
A simple, rapid, accurate and precise method is developed for the quantitative
simple, specific, accurate and precise reverse phase high performance liquid chromatographic method was developed and validated for the estimation of Lorazepam in tablet dosage form. An Inertsil ODS Ultrasphere
established as per ICH recommendations by validated and stability indicating reverse phase liquid chromatographic method. Bortezomib is subjected to stress conditions of acid, base, oxidation, thermal and photolysis…
novel comparative force degradation ultra-performance liquid chromatographic assay method was developed and validated for Telmisartan and its degradation products. Telmisartan was subjected to acid (0.1M HCl), neutral…
simvastatin in bulk drug. The developed method was successfully applied to the simultaneous quantitative analysis of the title drugs in tablet dosage form. The chromatographic separation was performed on Kromasil
volume) as a developing system with UV detection at 254 nm. Factors affecting the chromatographic separation have been studied, moreover the method has been validated as per ICH guidelines ... drugs in their different…
accurate, selective and precise chromatographic methods, namely TLC-densitometric method & RP-HPLC method & were developed and validated for the simultaneous determination of Amlodipine besylate and Perindopril Arginine…
thin-layer chromatography (HPTLC) method has been established for simultaneous analysis of Domperidone (DMP), Paracetamol (PCM) and Tramadol Hcl (TMD) in tablet dosage forms. The chromatographic separations were…
simple, rapid and sensitive reversed-phase liquid chromatographic method was developed and validated for the simultaneous determination of ascorbic acid (ASC) and salicylamide (SAL) in their combined dosage form
chromatographic methods have been developed for determination of pazufloxacin in human plasma with two co-administered drugs, cefoperazone and sulbactam sodium. First method depends on reverse phase high performance…
sensitive, selective reverse phase method was developed for the quantitative determination of six potential impurities in Androstanolone active pharmaceutical ingredient. Efficient chromatographic separation was…
rapid and effective high performance liquid chromatographic (HPLC) method with accelerated solvent extraction (ASE)-solid phase extraction cleanup was developed for the determination of sulfonamide and sarafloxacin…
accurate reverse phase HPLC method has been developed for the simultaneous determination of Metoprolol succinate (METO) and Olmesartan medoxomil (OLME) in tablet dosage form. The chromatographic separation was achieved…
stability-indicating LC assay method was developed for the quantitative determination of Doxazosin mesylate (DXM) in pharmaceutical dosage form in the presence of its degradation products and kinetic determinations were…
simple and reproducible high-performance liquid chromatographic method was developed for simultaneous determination of sulfamethoxazole (SMX) and trimethoprim (TMP), which are also known as cotrimoxazole, in tablet and…
simple, highly sensitive, precise and accurate high-performance liquid chromatographic (LCMSMS) method with mass detection was developed and validated for the rapid quantification of metaxalone (CAS Registry ... terms…
simple, sensitive and rapid high-performance liquid chromatography method with ultraviolet (UV) detector was developed and validated for the analysis of riluzole (RLZ) in rat plasma. The plasma sample, spiked…
study is development and validation of a method for the simultaneous estimation of raloxifene (RAL) and its two active metabolites, raloxifene-4-glucuronide (R4G) and raloxifene-6-glucuronide ... spectrometry operated…
Accurate, simple, sensitive, reproducible and specific liquid chromatographic method has been developed for estimation of BITS-17 in rat plasma and other biological tissues using β-naphthol as an internal
A method combining pretreatment by automated solid-phase extraction (SPE) with high
reversed phase high-performance liquid chromatographic method was developed and validated for the quantitative determination of two antiviral drugs viz. lopinavir and ritonavir. Chromatography was carried out by…
precise high performance liquid chromatographic method for the simultaneous determination of ezetimibe and Atorvastatin in API (active pharmaceutical ingredient) and formulation has been developed and validated…
HPLC method that is based on zwitterionic hydrophilic interaction liquid chromatography (ZIC-HILIC) coupled with ultraviolet detection was developed, optimized and validated for the simultaneous determination of…
Five methods were developed for simultaneous determination of Salmeterol xinafoate (SAM) and
flight mass spectrometry was developed and validated for quantitative determination of amantadine and memantine in drug substances and products. Materials and methods: The method was based on time of flight ... electron…
For authors and organisers
Find the right journal for your paper and submit your manuscript.