RPHPLC method was developed for the quantitation of emtricitabine in capsule dosage form. The quantification was carried out using Gracesmart RP18, 5μ (100mm x 4.6mm). The mobile phase comprised
sensitive, selective, precise and stability indicating high-performance thin-layer chromatographic method for quantification of Drotaverine and Aceclofenac in pharmaceutical dosage form has been established and…
mobile phase at a flow rate of 1.4ml/min at an ambient temperature. Quantification was achieved with ultraviolet (SPD-10AV) detection at 209 nm over the concentration range ... glacial acetic acid)…
concentration range of 20-120 μg/mL. Limit of detection and limit of quantification was found to be 6.13 μg/mL and 18.57 μg/mL respectively. The % recovery ranged within
substance was chosen for this study and limit of detection (LOD) and limit of quantification (LOQ) values were 0.09 μg/mL and 0.30 μg/mL respectively. The average accuracy value
developed method was validated for linearity, accuracy, precision, limit of Detection (LOD), limit of quantification (LOQ) and robustness. The linearity ranges were 0.5-2.5 μg/spot
acid, flow rate was 0.9ml/min and column was maintained at 55 0C. Quantification and linearity was achieved at 244 nm over the concentration range of 1.6 – 80μg
acetic acid, flow rate was 0.75 ml/min and column was maintained at 500C. Quantification and linearity was achieved at 271 nm over the concentration range
measurement of absorbance at 284 nm and 292 nm as two wavelengths selected for quantification of Domperidone and Pantaprazole. The second method is Absorbance ratio method based on the measurement ... absorbance at…
developed for the estimation of valacyclovir in bulk drug and pharmaceutical dosage form. The quantification was carried out using C18 column and mobile phase consisting of 0.067 M phosphate buffer
range of 7-27 μg/ml. The limit of detection (LOD) and limit of quantification (LOQ) were found to be 0.31 μg/ml and 0.92 μg/ml, respectively. The percentage
Reverse Phase High performance Liquid Chromatography was developed for separation and quantification of entacapone from 1-[2-Cyano-3-(3,4-dihydroxy-5-nitropheyl-1-oxo-2-propenyl piperidine (entacapone
spot for hydrochlorothiazide. The limit of detection and the limit of quantification for the irbesartan were found to be 22.19 and 73.98 ng/spot respectively and for hydrochlorothiazide
found to be 50-150 μg/ml, with the regression coefficient of 0.9993. Quantification was done by calculating area of the peak and the detection limit and quantitation limit ware
assessed by evaluating the recovery, repeatability, reproducibility, linearity and limits of detection and quantification. The proposed method has a potential for application to drug substances which may contains traces
measurement of absorbance at 367 nm and 292 nm as two wavelengths selected for quantification of AMB and TEL. The second method is first order derivative based on the measurement ... absorbance at 270nm and 295nm as two…
detection wavelength was 268 nm. The proposed method has permitted the quantification of Rimonabant in the linearity range of 10- 50μg/ml .The column was maintained at ambient temperature
adjusted to3. Flow rate was maintained at 1 ml/min at an ambient temperature. Quantification was achieved with ultraviolet (DAD) detection at 255 nm. The retention time obtained for Atazanavir
For authors and organisers
Publish, present and keep up with your field
Find the right journal for your paper and submit your manuscript.