studied using batch methodology. Equilibrium isotherm studies was analyzed by the Langmuir, Freundlich and Halsey isotherm models while the Pseudo First Order (PFO), Pseudo Second Order (PSO) and Intraparticle Diffusion…
Nickel (II) ion from aqueous solution onto CMAC are fitted to Langmuir, Freundlich and Temkin isotherm models and the model parameters are evaluated. The results ... showed that the equilibrium adsorption of CMAC is…
described by pseudo-first order model by AC1 and intra-particle kinetics by PMPs. The adsorption constants were evaluated according to Langmuir, Freundlich, Temkin ... isotherm models. The experimental adsorption data…
order and pseudo-Second-order) were tested to investigate the adsorption behaviors and Freundlich and Langmuir models to analyze the adsorption equilibrium. Promising performances were pointed
oleifera could best be modelled by the Freundlich isotherm whereas the Langmuir model is slightly better than the Freundlich isotherm in the case of the M. Stenopetala. The energies
kinetic data were analyzed by pseudo-first-order and pseudo-second-order kinetic models. The Freundlich and Langmuir isotherm models were used to describe the equilibrium data. FTIR spectra
ions by the jengkol shells analyzed using two isotherm models , namely Langmuir and Freundlich isotherm models . The absorption of both the metal ions tend to follow the Langmuir isotherm models
decreased with increase of initial cadmium (II) concentration and temperature. Langmuir, Freundlich and Dubinin–Radushkevich (D–R) isotherm models were used to analyze the equilibrium data ... Langmuir isotherm model…
adsorbate. The sorption process was analyzed using 6 different isotherm models (Langmuir, Freundlich, Harkins-Jura, Sips, Jossens and Baudu). The experimental data were best fitted into Jossens isotherm model ... order…
model. The adsorption data follow the adsorption equilibrium was described well by the Freundlich isotherm model. The results of SEM and AFM analysis show that particle size is less than
respectively. The experimental results were analyzed in terms of Langmuir and Freundlich isotherms. The Langmuir isotherm model fitted well ... data of Ni(II) biosorption by Cosmarium panamense biomass as compared to…
ions depends on metal ion concentration, adsorbent dosage and contact time. Langmuir and Freundlich adsorption models were used to model the equilibrium data. Based on linear regression value ... adsorption fits…
batch removal of Ni (II) and Cr (VI) ion from aqueous model solution using scolecite natural zeolite (SNZ) has been investigated under different operational parameters like initial heavy metal ... were measured and the…
temperature of 30, 40 and 50oC are fitted to Langmuir and Freundlich isotherm models. Langmuir model fitted the equilibrium data better than the Freundlich isotherm. Experimental data were used
agreement with the pseudo-second-order kinetic model; and analyzed by Langmuir and Freundlich isotherm models to investigate the adsorption of copper and cadmium ions on rice husk. The adsorption
first-order and pseudo-second-order kinetic models as well as Langmuir and Freundlich isotherm models. The kinetic data followed the pseudo-secondorder equation; the isotherm data were described
adsorption process were examined. The equilibrium adsorptiondata were analyzed using two isotherm models (Langmuir and Freundlich), two kinetics models (pseudo-first order and pseudo-second order) andthermodynamic…
found the order of action. The equilibrium data was correlated to Temkin, Freundlich and Langmuir models and the maximum Freundlich adsorption capacity was found
steady-state data, the Langmuir isotherm model showed a better fit than the Freundlich isotherm model. Fixed-bed adsorption experiments revealed the influence of IPA concentration and volumetric flow rate
steady-state data, the Langmuir isotherm model showed a better fit than the Freundlich isotherm model. Fixed-bed adsorption experiments revealed the influence of IPA concentration and volumetric flow rate
first order model. The Langmuir isotherm model fitted the data more than the Freundlich isotherm model, as gathered from their R2 values. Result obtained indicated that the sorption efficiency
kinetic model. Equilibrium adsorption capacities were determined by fitting experimental data to isotherm models: Langmuir, Freundlich, Dubinin-Radushkevich isotherm and Temkin models. Based on the calculated…
analyzed using adsorption isotherm models and better fit is obtained with Freundlich isotherm model. Crosslinked network is found to be an efficient device for facile sequestering of Cd2+ ions from
contact time and initial dye concentrations. From the experimental data the Langmuir, Freundlich and Temkin adsorption isotherm models were arrived and the Pseudo second order, Elovich and Intra-particle diffusion…
For authors and organisers
Publish, present and keep up with your field
Find the right journal for your paper and submit your manuscript.