Penetrating knife in the maxillary sinus: Report of a rare case
dental origin (1) like tooth (2), dental amalgam (3), gutta percha points (4), titanium implants (5,6), dental bur (7,8), dental paste (9) and dental impression materials
Articles, journals and conferences in one search. An exact title, DOI or ISSN is listed first.
In the search box: "exact phrase" · -leave out · OR · prefix* · title: author: journal:
dental origin (1) like tooth (2), dental amalgam (3), gutta percha points (4), titanium implants (5,6), dental bur (7,8), dental paste (9) and dental impression materials
There is an increasing demand for orthopedic implants owing to the increasing numbers of aging population. Titanium alloy (Ti6Al4V) is a common material used for orthopedic implants owing ... important to improve the…
metal ions released from titanium orthodontic mini-implants. Methods: Total 15 titanium mini-implants were used in the current study, which were divided equally into 3 groups (5 mini-implants
sound conduction and a hearing processor. The component implanted in the soft tissue of the outer ear is the titanium tube system, for which the outer diameter of the central ... objective is to ensure that the…
This study considers the effect of stress shielding on the bone-implant interaction and optimize the stiffness of titanium scaffolds. When the loads on the implants could not be transferred ... stress shielding effect…
integration in the human body. To ensure optimum boneapposition, the surface of the implant material (e.g. titanium) should be modified to include desirable micro-, sub-micro- and nano-topography features
tibia at 2 and 6 weeks of implantation time. Method: 48 commercially pure titanium screw shaped implants were placed in 24 healthy adult New Zeeland rabbits, each rabbit received
traditional histology and which additional information could be accessible with multimodal imaging.Therefore, model implants fabricated of titanium coated polyetheretherketone (Ti/PEEK) were inserted in the mandible of…
A key feature of medical devices, including implants, is their multifunctionality to
influence the biological response. By encouraging osteoblast development and bone growth at the implant surface, this strategy hopes to integrate the orthopaedic surface with the surrounding bone tissue. The requirement…
spiral-shaped macrostructure and the irregular microstructure of the titanium surface, promoted by the surface-blasting treatments, make the implant more favorable to adhesion and retention of plaque when exposed…
analyses revealed the occurrence of ORR at the surface of titanium, the main materials of the conventional medical implants. The controlled generation of H2O2 noticeably ... enhanced in vitro angiogenesis even in the…
developing metal-free restorations and are now considered as promising alternatives to titanium as dental implants. Zirconia indeed possesses high strength and good toughness for a ceramic, together with excellent
Titanium (Ti) is commonly used in dental implants applications. Surface modification strategies are being followed in last yearsâÂ?Â? in order to build Ti oxide-based surfaces that can fulfill ... tool for the growth of…
bridges, especially in areas of the mouth where aesthetic concerns are less critical. Implant materials Titanium and titanium alloys: Titanium is the gold standard for dental implants
implants becomes a lifesaving procedure. A primary obstacle to a wider use of biomaterial implants is their risk of infection and unsuccessful tissue integration with the surface of biomaterials ... solvent, and they…
tolerate metal implants as such the search for an alternative to titanium and titanium alloy implants has been active for over twenty years. Bioceramics such as Y-TZP Zirconia have
focused on in vitro cell differentiation and surface characteristics in a magnesium coated titanium surface implanted on using a plasma ion source. Methods & Materials: 40 commercially made pure titanium discs…
Owing to good biocompatibilities, resistance to corrosion and mechanical properties, Titanium (Ti) implants are popularly used in dentistry. The fundamental aspect in the performance of an implant is the mechanical
predict proper loading time. Methods: RF assessments were performed on 15 non-submerged titanium dental implants in 10 mandibles. Implant stability was measured at placement and weekly until week
fixed carbon table. Following dorsal preparation of the vertebral region, the surgeon implanted small titanium screws in the vertebrae. The screws served as fiducial markers. Image data acquisition and image
application of binarization technique. The uniqueness feature for insertion of the titanium dental implant contains several teeth in different portions. After the process of the binary image technique, the colourful
Statement of the Problem: Now-a-days, most of implants are made of titanium and its alloy. However, the process of chemical bonding between the biomaterial and surrounding bones ... infections and insufficiency of the…
values at 21 days. Conclusions: In conclusion, the topography and surface characteristic of modSAE implant showed a tendency to improve bone tissue integration and also contributes to maturation of collagen ... days…
also assessed in the three groups. Thirty and 60 days after the implantation of titanium plates and composite materials, no rabbits succumbed to inflammatory reactions, adverse reactions, abnormal blood routine…
For authors and organisers
Find the right journal for your paper and submit your manuscript.