with GPS and topographic maps data sets indicates a strong positive correlation 0.8, 0.827 respectively. Therefore, a Multiple Linear Regression (MLR) model was used to readjust ASTER data based
range of 100-500 μg/ml, in the linearity study regression equation was found to be y = 97.17x - 3.660 & correlation coefficient was found to be 0.999. This method
method. Calibration curves were linear in the range of 4–20 μg/ml for Ofloxacin and 5-25 μg/ml Azithromycin for absorbance ratio method. Correlation coefficient found
quercetin equivalent) and flavonoids (4.8 mg/g quercetin equivalent) respectively. A positive linear correlation was observed between these polyphenols and the free radical scavenging activities
multistage shuttle run test were performed on 183 school badminton players. Linear regression and correlation tests were performed using body mass index, practiced duration, age category, level of performance, additional
that the ADDS strongly correlated with "true-positive" and "true-negative" responses for determining the probability of a vestibular disorder (r =0.95). A stepwise linear regression was conducted
possible score (100%). The univariate linear regression analysis showed that age and media screen time were inversely correlated with the DQI score; whereas a direct correlation with parental educational level…
nonequilibrium open system is studied in the projection operator formalism. The environment may linearly deviate from its initial state under the reaction from the open system. If the relevant statistical ... production…
subjected for statistical analysis. Significant correlation between stature and the entire hand dimensions was established except hand breadth (HB) in the females. Independent linear regression equations to calculate…
predictive capacity of a given model based on the correlation between predicted outcome and GF presence. Five statistical models were compared using this procedure. Results After evaluating 6 real databases ... identify…
QSAR studies were performed using three statistical methods: the multiple linear regressions, giving square of correlation coefficient r2=0.8386, cross validated squared correlation coefficient q2=0.7218 and predictable…
called robust AIC (Akaike Information Criteria) for automatic selection of smoothing. Robust Pearson correlation coefficient and mean-squared error are employed to determine the polynomial degree of piecewise regression…
method was found linear within the range of 60-140 µg/ml for Moxifloxacin and 48-112 µg/ml for Keterolac Tromethamine with correlation coefficient 0.999 and 0.998 respectively. Percentage
259nm. After method development, the interference of other active compounds and excipients, repeatability and linearity were investigated. Retention times of atorvastatin and amlodipine besylate were found…
detection wavelength 246nm. A linear response was observed in the range of 6.4 µg/ml-9.6 µg/ml with correlation coefficient of 0.999, this method can be used as stability
fluorescence mode. The peak heights at Rf 0.648 ± 0.01 gave a linear range from 200-1000μg/ml correlation coefficient R2± SD = 0.973 ± 0.024. The LOD and LOQ were found
drug was carried out at 274 nm. GFN obeyed linearity in concentration range 800 – 2800 ng/band with coefficient of correlation 0.999. The Rf for GFN was found
array detection. Analytical and Bioanalytical Chemistry 407:4219-4226”. In this paper, a selective, linear, accurate and precise supercritical-fluid chromatography coupled with diode-array detection method was developed…
calibration curve is A=0.0906+0.2579 c (μg/mL), with a linear regression correlation coefficient of 0.9993. The molar absorptivity was 1.33 × 105 l/mol cm. The limits of detection
Both SEVR and ED% had negative correlation with HR using Pearson's correlation and Stepwise Linear regression p<0.001. There was no significant correlation with age p=0.143. No significant
average values of coma, spherical aberration (SA), trefoil, CCT and IOP were not significant. Linear regression revealed significant associations between change (y) in trefoil and pre-enhancement value of trefoil…
from the sclera in the superonasal, superotemporal, inferonasal, and inferotemporal quadrants. Product moment correlation and linear regression were used to examine correlations between the measurements. Results: 50 eyes
For authors and organisers
Publish, present and keep up with your field
Find the right journal for your paper and submit your manuscript.