214Bi) did not reflect its concentration. Radon exhalation rate was calculated using a-track detector. The annual effective dose was calculated for the different personal ages. The babies (< one year
detection was carried out at 241 nm using photo-diode array detector. The drug was subjected to oxidation, hydrolysis, photolysis and heat to apply stress condition. The validation element investigated
carried out in the range of 200 to 600 nm using photodiode array detector and set at 240 nm for alphalipoic acid and at 266 nm for Methylcobalamin and further ... analysis was carried out using a UV detector. These…
concentration range 1.0-2.9 μg/mL were determined at 227 nm using UV spectrophotometer detector. The recover were 107.96, 100 and 88.78% with RSD below 1.5% for the three assayed
flow rate of 1ml/min. The measurements were made at 243.0 nm using UV detector. The linearity range was found to be 5-80 μg/ml for Drotaverine hydrochloride
administration of cysplatin, the patient presented severe abdominal pain and calf claudication. A multi detector computed tomography (MDCT) revealed a floating mass in the infrarenal abdominal aorta. Considering the…
found the sensitivity, specifity, positive and negative predictive values (PPV, NPV) of handheld metal detectors to be 88.6%, 100%, 100% and 55.5% respectively (95% confidence intervals) in patients who ingested
sugar beet. Since with other molecular methods, equipping laboratories with a thermocycler or expensive detector systems is unavoidable, this assay was found to be a simple, cost-effective molecular method
HPLC auto sampler system containing UV- visible and fluorescence detector with Empower software and Zorbax SB Phenyl C18 column (4.6×150 mm). Detector Fluorescence detector for Ethinylestradiol UV detector ... Emission…
maintained with o-phosphoric acid. The method was optimized using multivariate technique and detector response was recorded at five different wavelengths. Chromatography was performed at ambient temperature by pumping
PGE1 and pGA1 respectively, using a multiwave UV detector. The method was validated for specificity, linearity, precision, accuracy, robustness and sensibility. Limits of quantitation were about
radionuclides 226Ra, 232Th and 40K has been determined by gamma-ray spectrometerwith NaI(Tl) detector. It was found that the average values of 226Ra, 232Th, 40K ranged between
atrazine in soil samples by high performance liquid chromatography equipped with ultra-violet detector and/or gas chromatography mass spectrometry. The method uses acetonitrile as the extracting solvent
organochlorine pesticides by using a gas–liquid chromatography equipped with an electron capture detector. The α, β, γ and δ isomers of HCH (Hexachlorocyclohexane) and metabolites of DDT (Di…
proteases was detected using both lectins, and gas chromatography coupled with flame ionization detector. The results indicate that the detection of glycocarbohydrates by gas chromatography is better after acetone…
response at selected wavelengths and concentrations of analyte in the solution. Linearity for the detector response was observed in the concentration range of 2-12 µg/ml for the method
liquid chromatographic method was developed for the enantiomeric separation of Cathine Hydrochloride with UV detector. The enantiomers of cathinewere baseline resolved onChiral packAD-H(250mm X4.6mm, 5um) column using
variation was analyzed with laser power and focal length. We use here plasma detector sensor for predetermined cutting speed. The full factorial method is used for cutting speed and surface
days period of incubation by dry weight of mycelia, Gas chromatography-Electronic capture detector (GC-ECD) and Gas chromatography-Mass spectroscopy (GC-MS) profiling for the metabolite detection. Simultaneously chemical
radon gas concentration were measured using CR-39 etch track detectors in both summer and winter times at different depths (25, 50, 75 and 100 cm) covering several geological formation
sample extract (2 μL) injected into the instrument was detected by Turbo gold mass detector (Perkin Elmer) with the aid of the Turbo mass 5.1 software. The important compounds obtained