chloroform crude extract was loaded in a column and was developed by gradient elution. The purified sample from the above column chromatography was subjected to preparative TLC. The result gave
achieved on a core shell technology C18 stationary phase. The method employed a linear gradient elution and the detection wavlength was set at 260 nm. The mobile phases consists
phase consisted of a mixture of 0.2% orthophosphoric acid, methanol, and acetonitrile in simple gradient elution. Ultraviolet (UV) detection was performed at 210 nm. Total run time
method used a Phenomenex Luna C18 column (250 × 4.6 mm; 5 µm) using a gradient elution of 1 mM ammonium acetate buffer and acetonitrile as the mobile phase with
methods use Phenomenox Luna (C‐18, 250 x 4.6 mm, 5 μm) column and gradient elution for both the methods. The aqueous mobile phase contained 0.02 M phosphate buffer adjusted
separation was performed on acquity UPLC, Kromasil C18, 50×2.1 mm, 3.5 μm using gradient elution of acetonitrile and 0.1% v/v Triethyl amine buffer (pH 3 ± 0.05) at flow
Mobile phase was pumped at a flow rate of 1.5 mL min−1 using gradient elution through prepacked Nuclosil, C18 (250×4.6 mm, 10 μm) column. UV detection was performed
6βHC) and free cortisol (FC). The use of 0.01% formic acid/isopropanol for binary gradient elution on a reversed-phase C18 column resulted in 3.1 and 5.0 times the peak
with a mobile phase of 0.1% phosphoric acid (0.1%) -acetonitrile in a gradient elution over 135 min using a PDA (205 nm) for analysis and compared with reference standards
separation was performed on Waters Acquity UPLC system and BEH Shield RP18 column using gradient elution of mobile phase A and B. 0.01 M phosphate buffer adjusted pH 3.0 with
Eternity TM C 18 UHPLC column (2.5 μm, 2.1 mm x 50 mm) using gradient elution of acetonitrile and ammonium acetate buffer (pH 6.70; 0.01 M) as mobile phase
Chinese proprietary medicine “Wuji Pill” (WJP). The analysis was performed by reversed phase gradient elution, using an aqueous mobile phase (containing 0.05 mol/L monopotassium phosphate and 0.1% aqueous phosphosnic
respectively. Retinol acetate is employed as the internal standard. The reversed phase method incorporates gradient elution with a mobile phase consisting of methanol and acetonitrile. Separation of vitamin compounds
centrifuged, and then clear solution was injected onto Zorbax C18 column. The mobile phase (gradient elution mode) consists of methanol, acetonitrile, and water (pH = 3.0); the eluents were monitored
mobile phase consisting of acetonitrile–0.02M ammonium acetate buffer (pH 4.5) in a gradient elution mode at a flow rate of 1 ml/min. The retention times for lamivudine
mixture of 0.2% ortho phosphoric acid and acetonitrile as the mobile phase in gradient elution technique. The retention time of Sumatriptan and Naproxen was found
hexane, ethylacetate and methanol and silica gel 70-230 mesh as adsorbent in a gradient elution - column chromatographic technique. The bulked fractions were subjected to antioxidant screening and brine shrimp
switch, the extracted drug was back-flushed onto a Zorbax SB-Aq analytical column, gradient eluted and finally detected after electrospray ionisation with multiple reaction monitoring (MRM) of the transitions
gallic acid in Phyllanthus emblica L. (Euphorbiaceae). A C18 column was used with a gradient elution of methanol and 0.1% (v/v) acetic acid in HPLC-grade water as mobile