acid) (7.0:2.0:0.5:0.5%v/v/v/v) as mobile phase. Quantification was achieved with HPTLC detection at 263nm over the concentration range of 200 to 1000 ng/ spot ... range of 98.00-101.11% for RIV. Both the methods are…
utilizing a mobile phase of acetonitrile and water containing 0.01 % v/v ortho phosphoric acid (in the ratio of 80: 20% v/v) with UV detection at wavelength ... flow rate 1mL/min. The proposed method was validated for…
simple, sensitive, precise and accurate high performance thin layer chromatographic (HPTLC) method has been developed for the simultaneous estimation of atorvastatin (AT) calcium, ramipril (RA) and aspirin (AS) in…
simple, sensitive and reproducible reverse phase high performance liquid chromatographic method has been developed for simultaneous estimation of Candesartan cilexetil and Hydrochlorothiazide in combined tablet dosage…
phase. The solution A contains phosphate buffer pH 3.1 and acetonitrile as Solution B. The developed RPLC method was validated with respect to specificity, linearity, accuracy, precision and high sensitivity ... with…
sensitive, accurate and rapid high-performance liquid chromatography with UV-visible detection (HPLC-UV) method for the determination of Gemfibrozil in human plasma has been developed. Gemfibrozil and internal standard…
reliable and sensitive isocratic stability indicating RP-HPLC method has been developed and validated for assay of Ezetimibe in tablets and for determination of content uniformity. An isocratic separation ... using a UV…
Egilent TC C18 (2) 250 x 4.6 mm, 5 μ column using mobile phase composition of water: acetonitrile (20:80 v/v) pH adjusted to3. Flow rate was maintained ... ambient temperature. Quantification was achieved with…
sensitive HPLC method with UV detection (206 nm) for routine analysis of alpha amyrin from Scoparia dulcis plant extract was developed. Chromatography was performed with mobile phase containing a mixture ... Limit of…
Simple, rapid, sensitive, accurate, robust & rugged stability indicating analytical method for determination of Erlotinib in pharmaceutical formulations is developed and validated by using UPLC & applied the developed…
phase liquid chromatographic (RP-LC) related substance method for SAdenosyl- L-methionine (SAMe) in active pharmaceutical ingredient was developed and validated. SAMe was subjected to stress conditions and observed…
convenient, rapid and sensitive method for determination of ester derivative of 7-theophyllineacetic acid with propylene glycol in rabbit serum was developed. The procedure involved liquid-liquid extraction ... column…
stability indicating RP-HPLC method was developed. The drug was resolved using a mobile phase of buffer (pH 2.5) and methanol in the ratios of 50:50 on a Thermo ... limit of Detection and the limit of quantitation were…
dosage form. The HPLC analysis used a reversed phase Kromasil C18 (150 x 4.6mm, 5μm) column and a mobile phase constituted of buffer and acetonitrile ... with orthophosphoric acid. The wave length of the detection was…
within 5 min run time. The stationary phase was conventional C18 column (250 x 4.6 mm, 5 μm). The detection was carried out at UV wavelength ... respectively. The proposed method is sensitive, simple and cost effective…
tablet dosage form. The HPLC analysis used a reversed phase Kromasil C18 (150 x 4.6mm, 5μm) column and mobile phase constituted of buffer and methanol ... water. The dual wavelengths of the detection were 235 nm& 254…
simple, specific, sensitive, rapid, accurate and precise RP-HPLC method was developed for the estimation of quetiapine fumarate in bulk and pharmaceutical formulations. Quetiapine fumarate was chromatographed on…
accurate, highly sensitive, precise, simple, efficient and reproducible, isocratic Reversed Phase-High Performance Liquid Chromatography (RP-HPLC) method was developed and validated for the quantitative determination of…
purple or methylene violet (i.e. reagent molecular ion having negative charge) in the aqueous phase at a suitable pH extractable into dichloromethane or chloroform in Method A and Method ... molar absorbitivity and…
simple, accurate, specific and sensitive reverse phase high performance liquid chromatographic method has been developed and validated for the simultaneous estimation of cefixime trihydrate and moxifloxacin…
simple and sensitive methods to determine atorvastatin calcium (ATO) and pioglitazone hydrochloride (PIO), in tablet dosage form, were developed and validated using reverse phase liquid chromatography (LC) and high…
with a mobile phase consisting of methanol-0.05% formic acid (90:10 v/v) with flow rate of 1.0 ml/min. Detection was carried out at 232 nm. The retention ... stress conditions including acidic, alkaline, oxidation…
phase at a flow rate of 1.0 mL min1, an injection volume of 20 μL and were detected at 254 nm using UV detector. A simple, selective and sensitive HPLC
androgens to estrogens in peripheral tissues. Since HPLC methods were more accurate, precise and sensitive, the present work describes a simple, precise and accurate analytical HPLC method for the estimation ... mobile…
For authors and organisers
Publish, present and keep up with your field
Find the right journal for your paper and submit your manuscript.