Identification of Methyl-biphenyltetrazole as a novel degradation product of irbesartan
degradants was achieved with Hitachi LC 6200 pump, LC Organizer injector, Kratos Spectroflow 783 detector and zorbax analytical column
Articles, journals and conferences in one search. An exact title, DOI or ISSN is listed first.
In the search box: "exact phrase" · -leave out · OR · prefix* · title: author: journal:
degradants was achieved with Hitachi LC 6200 pump, LC Organizer injector, Kratos Spectroflow 783 detector and zorbax analytical column
samples without compromising the accuracy. It was further accomplished with HPLC/UV detector system which was validated to be adequately precise, effective, selective and sensitive with comparable/higher criteria
control. Coenzyme Q10is monitored at a wavelength of 275 nm.This method achieves a linear detector response for peak height measurements over the concentration range ... oxidized coenzyme Q10are monitored at a…
samples without compromising the accuracy. It was further accomplished with HPLC/UV detector system which was validated to be adequately precise, effective, selective and sensitive with comparable/higher criteria
Multi detector X-ray computed tomography (MDCT) has been widely adopted by forensic pathologists for performing ?near virtual autopsies? where the cause of death can in some circumstances be determined ... body. The…
most accurate imaging modality in detecting the drug container. Virtual autopsy" performed with multi detector computed tomography (MDCT) can also aid forensics teams in determining if a person has drowned
have been carried out under narrow-collimated-beam method with scintillation detector. The values of mass (μ/ρ) and linear (μ) attenuation coefficients thus obtained are found
hexane in an ultrasonic bath and analyzed using gas chromatography with a flame ionization detector. The results suggested that the wasp species have distinct chemical signatures as the linear hydrocarbons
resolution was flow rate 1.0 mL/min, column temperature at 22?C and detector wavelength at 247 nm. Both the drugs were well resolved on the stationary phase
used at a flow rate of 1.0 ml /min. DAD detector was programmed at 230 nm for run time 7 min. All the validation parameters were in acceptable range
measurement performed under narrow collimated beam counting geometry with scintillation spectrometer as a photon detector. The Mass attenuation coefficient and linear attenuation coefficient values reported in this work…
Linear and mass attenuation of 662 KeV gamma radiations from alcohol ethanol
effluents were monitored at 243 nm. The retention time was 3.725 min. The detector response was linear in the concentration of 20-120 μg/mL. The respective linear regression equation
overview covers the x-ray tube, adaptive exposure techniques, beam and rotation geometry, detector technology and reconstruction algorithms. Furthermore, the combination of CBCT with optical imaging is discussed, the…
rapid reverse phase-high performance liquid chromatography (RP-HPLC) method with UV-Visible detector has been developed and subsequently validated for the simultaneous determination of tenofovir disoproxil fumarate…
flow rate of 1.2 mL/min. Detection was carried out using a PDA detector at 218 nm. Parameters such as linearity, precision, accuracy, recovery, specificity and ruggedness are studied
Linear and mass attenuation of 0.36 MeV gamma radiation from alcohol ethanol
catalyst at 800c. The product was analyzed by Gas Chromatography and with FID Detector. The conversion of p- nitrobezaldehyde to p-nitrobenzoic acid and p-nitrobenzyl alcohol was found
quantified by inductively coupled argon plasma/optical emission spectrometry (ICP-OES) with solid-state detectors. The two algal species under study provide a great amount of essential elements and there
most suitable one since it produced symmetrical peaks with high resolution. The UV detector response of ROSUVASTATIN and AMLODIPINE was studied and the best wavelength was found
HPLC separation was carried out by reverse phase chromatography on Shimadzu HPLC, 10-At detector with hypersil ODS C18 Column 250 X 4.6 mm (particle size of 5μ) and constant
A sensitive, specific, precise and cost effective High Performance Liquid Chromatographic method
expression of downstream signaling molecules. Therefore, insect Ors hold great promise as detectors in a biosensor for detection of volatile chemicals. Among insects, the olfactory system of Drosophila is presently
yields sensors with nanometer-sized dimensions, which limits the size and quantity of deposited detector elements. Llama antibodies are the smallest antibodies available today, and can serve as a detector
this in situ structural transformation, we have used simultaneous QCM-D monitoring and four-detector optical reflectometry to determine the antiviral mode of action of the AH peptide. The combination
For authors and organisers
Find the right journal for your paper and submit your manuscript.