solvent. The method was validated for specificity, linearity, accuracy, precision, robustness and ruggedness. The detector response for the Curcumin was linear over the selected concentration range
buffer (pH 4.5) and acetonitrile (70:30) at an absorption maxima 247nm. Linearity for detector response was observed in the concentration range of 50- 150% of test concentration. Correlation coefficient
simvastatin respectively. The plate was scanned and quantified at 217 nm. The linear detector response was observed between 2000 ng/spot to 7000 ng/spot and 250 ng/spot
using a flow rate of (1mL/min). Detection was carried out using a UV detector set at 242 nm. A linear relationship between mean peak area and concentration of Repaglinide
flow rate of 1.0 mL/min. Detection was carried out using a UV detector at 302nm. The total chromatographic analysis time per sample was about 7.0min with esomeprazole eluting
ambient temperature. The detection was carried out at 230 nm using waters UVVisible detector. The calibration curve was linear in the concentration range of 4–20mg
sample extract (2 μL) injected into the instrument was detected by Turbo gold mass detector (Perkin Elmer) with the aid of the Turbo mass 5.1 software. Results
methanol, acetonitrile, and water (pH = 3.0); the eluents were monitored by photodiode array detector (wavelength set at 265 nm). The relationship between the concentration
after administration. Plasma concentrations of acyclovir were determined using HPLC coupled to a fluorescence detector. The test and reference formulations were to be considered bioequivalent
aqueous extracts. Liquid chromatography with mass spectrometry and High performance liquid chromatography with UV detector were used to identify and compare the main ingredients ratio between Huanglian and Yunlian…
eggplant for pesticidal contamination was carried out on Gas Chromatograph-Electron Capture and TID Detector with capillary columns. Eggplant was found contaminated with monocrotophos, phorat, quinalphos, pendamethalin…
present study solid-state nuclear track detectors (LR-115 Type-II) ( from Kodak France) is in order to determine the soil gas radon profile in areas of middle shivaliks active
taken from Tube wells. The measurements were performed by RAD7 an electronic radon detector manufactured by DURRIDGE COMPANNY Inc. The radon concentration in these samples is found to vary from
been undertaken for the purpose of health risk assessments. RAD7 an electronic radon detector (Durridge co. USA) was used to estimate the indoor radon concentration levels in dwellings of Northern
small half life. In this comparative study Solid State Nuclear Track Detectors (SSNTD’s) based twin chamber dosimeters were used for estimating radon (222Rn), Thoron (220Rn) gases and Inhalation dose ... twin chamber…
Delhi) and at Dadri, (U.P.) India. LR-115 type-II solid state nuclear track detectors fixed on a thick flat card were exposed in bare mode. Keeping the radiation hazards
locations of oil-field in Basra governorate. Two types of Solid State Nuclear Track Detectors were used in the measurements which are CR-39 and LR-115 type
10keV to 1500keV gamma-rays photons have been measured using the HP (Ge) photon detector. The values of μ and μ/ρ thus obtained are found to be in good
compound eluted isocratically at a flow rate of 1.0 ml /min. The UV detector was set at 210 nm for the detection of pregabalin. The method was linear over
transmission measurements performed under narrow-beam counting geometry with HP (Ge) as a photon detector. The mass attenuation coefficient values reported in this work are found to be in good
glaucoma. In this article, a high performance liquid chromatography (HPLC) method with UV-Visible detector wavelength (254 nm & 295 nm) for Dorzolamide Hydrochloride & Timolol maleate was developed and validated
extracted compound is UV inactive, High-performance liquid chromatography (HPLC) with Evaporative Light Scattering Detector (ELSD) coupled to electrospray ionization mass spectrometric (ESI-MS) detection in the positive…
hydrochloric acid]. Detection was carried out at 267 nm using a Photo Diode Array detector. Fenugreek seeds and two marketed herbal formulations were subjected for HPLC analysis of Trigonelline. Results ... were found…
For authors and organisers
Publish, present and keep up with your field
Find the right journal for your paper and submit your manuscript.