simple and rapid high performance liquid chromatography (HPLC) method was developed and validated to determine uridine, metabolite of citicoline, in human plasma, and applied to the pharmacokinetics and bioequivalence…
quantified using a validated method employing liquid chromatography with tandem mass spectrometry with the lower limit of quantification of 0.25 ng/mL. All of the pharmacokinetic parameters were investigated using
until time of analysis. Ciprofloxacin concentrations in subjects’ plasma were determined by using a validated HPLC fluorescence technique. Confidence intervals (90%) for the peak plasma concentration (C max ) and area…
points up to 120 hours after dosing. Olanzapine plasma concentrations were quantified by a validated method employing liquid chromatography with tandem mass spectrometry (LC-MS/MS). Results: 24 volunteers completed…
Plasma quetiapine concentrations were determined by using a validated LC-MS/MS method. Pharmacokinetic parameters were estimated using the WinNonlin ® software with non- compartment model analysis. The mean
hours. Plasma concentrations were determined by a validated high-performance liquid chromatographic method with fluorescence detection and pharmacokinetic parameters were obtained by non-compartmental approach. Analysis…
hours after dosing. Plasma samples were analyzed by validated liquid chromatography with tandem mass spectrometry method. The pharmacokinetic parameters
intervals and analyzed for esomeprazole concentrations using a validated HPLC method. Non-compartmental method was used to determine different pharmacokinetic parameters. Obtained mean (SD) values for the test and…
assessment of adverse events, and laboratory tests. Imatinib plasma samples were analyzed employing a validated HPLC method using MS/MS detection. For a 400 mg dose of Imatinib, the analytical ... events, safety results…
concentrations of furosemide were determined with a validated method by liquid chromatography coupled to mass spectrometry (LC-MS/MS). We obtained the parameters
buoyancy term. The perturbation method of solution is obtained in terms of buoyancy parameter N valid for small values of N. The flow is analysed for three cases having
Birnbaum Saunder’s distribution to obtain weighted and length biased distribution. To obtain a valid weighted probability distribution the transformation was made. The statistical distribution of Zinc concentration in…
parameters by regression analysis. Structural requirements for maximal binding affinit y to a novel site of α 2 δ subunit were derived. The leave –one –out cross validation method
method. The best QSAR models were further validated by a leave one out technique as well as by the calculation of statistical parameters for the established theoretical models. To confirm ... used. High agreement…
routine estimation of moxifloxacin hydrochloride in the tablets available in market and was validated for various parameters according to ICH guidelines. moxifloxacin hydrochloride was estimated at 292 nm by densitometry
standard are considered. The model is a useful tool for the design of MAC parameters and to select the better topology. Personal Area Network (PAN). A collection of cooperating devices ... portion of the super frame is…
drugs were in good agreement with the labelled claim of the formulations. The method validation parameters checked as per the ICH guidelines. Thus the methods are specific and sensitive
respectively. The optimum experimental parameters for the reaction have been studied. The validity of the described procedure was assessed. Statistical analysis of the results has been carried out revealing high
Least Squares regression (PLR) analysis were generated to find out correlation between the physicochemical parameters and the biological activity. Multiple linear regression (MLR) coupled with stepwise variable…
inlet and outlet and the inlet flow velocity. Poorly designed or specified hydraulic parameters may lead to short circuiting and dead regions within the pond. This in turn impacts ... dispersion coefficient using…
equati on of y = 0.1546*X - 0.00414; ( r 2 = 0.999). The method developed was validated for i nter and intra day variation, limit of quantitation studies. The SD values ... esomeprazole was found to be of 1.00 g /ml…
analytical performance parameters suggested by the International Conference on Harmon ization. All validation parameters were within the acceptable range. The developed methods were successfully applied to estimate the…
For authors and organisers
Publish, present and keep up with your field
Find the right journal for your paper and submit your manuscript.