Waters 2695 separation module HPLC system with Waters 2487 Dual wavelength Absorbance detector. The column used was a stainless steel column of dimension 15 cm x 4.6 mm, packed with ... bonded to porous silica ( Make…
gradient High performance liquid chromatography (HPLC) method with UV detector was developed for the determination of drug related substances and which find their origin during the manufacture of the active
isocratic HPLC, Monitoring was done by a UV detector at 239 nm. Retention time of DOX and SAL was found to be 3.233 min. and 2.19 min. respectively. The method
analysis was performed at a wavelength of 220 nm using Photo Diode Array (PDA) detector. Two peaks were obtained (FST-A and FST-B) for the corresponding enantiomers. The retention
isocratic solvent mixture as mobile phase followed by quantification with mass detector in selective reaction monitoring mode using electro spray ionization mode (ESI) as an interface. The method was fully
guidelines. The mean recoveries from tablet formulations were between 99-101%. The detector responses were found to be linear in the concentration range of 80-120 % of the test concentration
amine) and acetonitrile was used as mobile phase. The analyte was monitored with UV detector at 275 nm. Typical retention time for prulifloxacin was found
determination of amino acid. A high performance liquid chromatography (HPLC) method with UV detector is developed for determination of individual 17 Amino acids content in bulk drug substance without derivatisation
short analysis time based on a transient signal measurement in a flow-through detector and an on-line carrying out difficult operations of separation, physicochemical conversion of analytes into detectable
with flow rate of 0.4 ml.min-1. The detection was carried out using UV detector set at 289 nm. For this method, Beer’s law is obeyed in the concentration
developing these future generation imaging systems, several interdependent tasks must be performed. First, radiation detectors must be simulated, designed and fabricated, and their geometrical configuration should be…
cyanopropylphenyl: 94% dimethylpolysiloxane as a stationary phase). The detector used was FID detector. The validation of p roposed method was also carried
drug from plasma. The detection was carried out using a UV-PDA detector at 226 nm. The method was validated for linearity, accuracy (recovery), precision, specificity and robustness. The linearity
particle size) column and the effluent was monitored by an ultra violet (UV) detector at 240 nm. The mobile phase used was acetonitrile: phosphate buffer (pH 7.0; 25.0mM containing
determination of amiodarone hydrochloride in tablet formulations. Liquid chromatography with a UV detector at a wavelength of 240 nm using a C18 column was employed in this study. Isocratic elution
flow rate of 1.0 ml/ min. Detection was performed at 254 nm using UV detector. The retention time for GFC was around 2.2 and AMB was around 4.5 min; separation
flow rate of 0.9 mL/min; the column temperature is 40°C and detector wavelength is 240 nm. The sample concentrations are measured on weight basis to avoid the internal
made for the measurements of radon and thoron by using solid state nuclear track detector based dosimeters. The average annual dose to the population of Bangalore city due to radon
indoor radon and thoron carried out in and around Vijayanagar, Bangalore, India using passive detector technique is presented. Measurements were carried out using twin cup radon-thoron dosimeter using small ... strips…
analytical column and determined by a quadrupole mass spectrometer detector operated under selected ion monitoring mode (SIM). Excellent linearity was found between 5 and 600ng
mmwith 10µ particle size. Column was maintained at 10ï‚°C.The UV/Vis detector was operated at 254nm. Flowrate of the mobile phase was 0.8ml/min. The method offers
Nova-Pak C18 cartridge at room temperature (RT), and detected by a photodiode array detector set at 284nm. The mobile phase consisted of 0.05% dibasic sodium phosphate, acetonitrile, and triethylamine
5ïÂÂmsteel at roomtemperature (RT), and were detected using a Water 2690 dual absorbance detector set at 247nm. The mobile phase, 0.05 M dibasic sodium phosphate buffer
utilizing aqueous solution of ortho-phosphoric acid (0.05 %). The detection was achieved using PDA detector at 210nm. The extraction recovery of itaconic acid was >89%and the calibration curvewas linear