recovery after breakthrough (BT) during N2 injection proves the importance of the solubility mechanism. Therefore, In this case, more precise analysis could be performed by applying the dissolution number instead…
ratio of 80: 20 v/v was used. The flow rate was 0.8 ml/min with injection volume of 20µl and effluent was monitored at 478nm. Retention time was found ... proposed method is precise and accurate and hence can be used…
method was developed and validated for routine analysis of tenofovir disoproxil in bulk and in pharmaceutical formulation. Isocratic elution at a flow rate of 1.0 mL/min was employed ... detection wavelength was 260 nm…
prepared and injected through guiding catheter into coronary artery. Maximum Duration of decreased BP and TIMI Grade were noted. A Pearson correlation analysis was conducted to examine whether there ... relationship…
wave and offshore wind farm fed to a power grid through a unified power flow controller (UPFC) to simultaneously achieve power-fluctuation mitigation and stability improvement. A PID controller ... using eigenvalue…
analytical method development, a reversed phase high performance liquid chromatographic method for routine analysis of dolasetron in dosage form has been optimized using analytical quality by design approach. A simple…
different One-quarter 5-spot network patterns were utilized for these tests. Image analysis technique were applied and saturation of phased with different color within the micromodel were measured. Micro ... emulsion…
Inertsil C18 column (250x 4.6mm; 5μm) at a flow rate of 1.5 ml/min. The injection volume was 10 μl and the peaks were detected at 205nm. The linear ... simple, fast, accurate, precise and reproducible and could be used…
time was 7 min. The influence of mobile phase composition, injection volume, mobile phase pH, flow rate, temperature, and detector wavelength on resolution was investigated. The method was validated according…
Solution-B (Acetonitrile) used at a flow rate of 1.0mL/min with injection volume of 10μL and the detection was done at 278nm using UV detector. The retention times ... guideline. In addition, the proposed method was…
flow rate of 2.0 mL min-1. In the developed RRLC method the resolution between Nevirapine and its two potential impurities was found to be greater than 4.0. Regression analysis ... with respect to test concentration of…
flow rate of 1.5 mL min-1. In the developed RRLC method the resolution between Zonisamide and its two potential impurities was found to be greater than 4.0. Regression analysis ... with respect to test concentration of…
flow rate of 0.5 mL min-1. In the developed RRLC method the resolution between Stavudine and its two potential impurities was found to be greater than 4.0. Regression analysis ... respect to test concentration of 0.5 mg…
ammonium acetate, pH adjusted to 8.5 by using triethylamine and delivered at a flow rate of 1.2 mL min-1. In the developed HPLC method the resolution (Rs) between Riluzole ... three potential impurities was found to be…
column with 20 μl injection volume. The mobile phase was consisting of methanol: Acetonitrile in ratio (90:10 V /V), and the flow rate was maintained at 2.5 ml.min-1.TCP ... RPHPLC can be used as a quality-control tool…
them is Garcinia mangostana L. The aim of this study is to find analysis method of α-mangostin from dichloromethane extract of green fruit latex G. mangostana L. that ... mobile phase methanol : formic acid 0,4 % (86…
analysis allowed to obtain reservoir properties depending on ionic composition of the injected water and clay-content of reservoir. It’s been shown that decrease of salinity of the injected ... salt concentration and…
combination delivered in gradient mode and quantification is carried at 270 nm at a flow rate of 0.6 mL min. In the developed LC method the resolution between bortezomib ... found to be greater than 2.0. Regression…
hydrate accumulations in the northern South China Sea. The feasibility analysis covers the requirements of proppant size, fluid injection rate, fracturing pressure, and well productivity. For the median grain size…
rapid assay of Benzoic acid in Bulk and Pharmaceutical Formulation. Isocratic elution at a flow rate of 1.0 ml/min was employed on symmetry ... detection wavelength was 254nm and 20μl sample was injected. The retention…
time was 18 min. The influence of mobile phase composition, injection volume, mobile phase pH, flow rate, temperature, and detector wavelength on resolution was investigated. The method was validated with ... Further…
For authors and organisers
Publish, present and keep up with your field
Find the right journal for your paper and submit your manuscript.