rapid and sensitive stability indicating Reverse Phase High Performance Liquid Chromatographic [RP-HPLC] method was developed for the estimation of Clopidogrel bisulphate [CGB] in presence of its oxidative, acid…
with a (R, R) - Whelk- O-2 chiral column under reversed phase condition. Mobile phase was 50 mM potassium dihydrogen phosphate (pH = 2.6) and methanol [60:40, v/v] using ... high sensitivity, accuracy and robustness as…
rapid, specific, sensitive ultra high-performance liquid chromatographic (UPLC) method has been developed for determination of Rotigotine impurities and its degradation products in Rotigotine Transdermal Patches. UPLC…
sensitive and selective solid phase extraction procedure for the determination of traces of Cd(II), Zn(II) and Ag(I) ions has been developed. An alumina-sodium dodecyl sulfate ... ion0.01–0.90 μg mL-1 for…
Highly sensitive, simple and accurate reversed phase liquid chromatographic and first derivative spectrophotometric methods were developed for determination of the non-steroidal anti-inflammatory drugnaproxen and the…
separation was achieved on reverse phase octadecylsilane C18 column with isocratic elution. The mobile phase consisted of a mixture of ammonium acetate and methanol (40:60) pumped at a flow ... linearity, sensitivity…
easy, sensitive and inexpensive method was evolved the usage of solid-phase extraction, together with high performance liquid chromatographic method with UV detection for determination of imazamox and imazethapyr…
simple, rapid, accurate and precise reverse phase-high performance liquid chromatographic (RP-HPLC) method has been developed and validated for the simultaneous determination of Terbutaline sulphate and Guaiphenesin in…
highly sensitive EIA utilizing a novel modified electron spin resonance (ESR) technique (modified ESR-EIA) was developed to detect HBsAg by measuring stabilized nitroxide radicals. Aim: to detect occult ... with…
simple, sensitive, rapid, precise, and accurate reverse phase high performance liquid chromatographic method had developed for the simultaneous estimation of guaifenesin and pseudoephedrine HCl in ER tablet dosage form…
domestic water bodies by using reverse phase High Performance Liquid Chromatography (HPLC) with ultraviolet absorption detection. The proposed method was quite reproducible and sensitive enough to detect the compounds…
pharmaceutical formulations. This method was accurate, precise and sensitive for the simultaneous analysis of Ceftalazone and Tazobactum. Optimization of the mobile phase can be done by using different combinations…
sensitive and selective High Performance Thin Layer Chromatographic (HPTLC), method was developed for the quantification of ambroxol HCl in human plasma. Six parameters from validation guidelines linearity, precision…
sensitive and rapid Ultra-Performance Liquid Chromatography (UPLC) method developed and validated for the determination of potential genotoxic impurity namely 2-(Chloromethyl)-4-methoxy-3,5-dimethylpyridine (CMDP) at…
ruggedness, sensitivity, solution stability. The method has been developed with ammonium dihydrogen phosphate buffer (pH 6.8) and methanol in a ratio of 65:35 v/v as mobile phase ... over Intersil ODS C18 column (250 mm…
Meanwhile mobile phase was potassium dihydrogen phosphate buffer pH (3.5)-acetonitrile (45:55, v/v) at flow rate of 0.4 ml.min-1. UV detection was carried ... with reported technique gives no significant divergence in…
mixture of Mobile Phase: A–Acetonitrile, B–0.1% Ortho Phosphoric acid in water, injection volume of samples was 1 μl and the UV detection λmax at 256 nm. The retention ... that achieved with conventional UPLC. This…
Reverse phase High-performance liquid chromatographic (HPLC) and UV spectrophotometric methods were developed and validated for the quantitative determination of Escitalopram oxalate and Flupentixol dihydrochloride in…
significant symptoms of peritonitis in addition to detected sensitivity, specificity, positive and negative predictive values and accuracy of , clinical, hematological and acute phase proteins (APPs) in single and…
simple, sensitive and reproducible high performance liquid chromatography tandem mass spectrometric method was developed and validated for the determination of itraconazole and hydroxy itraconazole in human plasma using…
simple, rapid, specific and sensitive Reverse Phase-HPLC method has been developed and validated for the simultaneous estimation of alfuzosin hydrochloride (ALF) and dutasteride (DUTA) in Bulk powder and pharmaceutical…
Simple and sensitive Ultra Performance Liquid Chromatography (UPLC) methods were developed, optimized and validated for the determination of 4-Nitro phthalimide, 5-Bromo phthalide and 5-Amino phthalide, 4-Amino…
mobile phase. UV detection was performed at 240 nm. The method was validated for linearity, accuracy, precision, specificity and sensitivity as per ICH norms. The developed and validated method
tablet dosage form. The mobile phase used was a combination of Acetonitrile: Water: Phosphate buffer (pH 3.0) (60:30:10, v/v/v). The detection of the combined dosage form ... both the drugs and relative standard…