score greater than 4 on the Michigan Neuropathy Screening Instrument (MNSI). Statistical evaluation included linear regression, analysis of variance, and Tukey’s post hoc test. Results: 100% of the control ... absent…
number. Methods used to derive genomic estimated breeding values (GEBV) were random regression best linear unbiased prediction (RR–BLUP) and a Bayesian LASSO (Least Absolute Shrinkage and Selection Operator…
energy expenditure [heart rate, physiologic cost index (PCI) and energy consumption was linear in BKA group, just as it is in normal group, but the slope is significantly steeper. Student ... difference between this…
cross-validated correlation coefficient (R2) is 0.79168 (RMSE=0.61459) and 0.70939 (RMSE=0.72938) respectively. Principal component analysis (PCA) was also used to reduce the dimension and linearly transform
results indicated non-fulfilment of Price’s law (correlation coefficient r=0.5597 after exponential adjustment vs.r=0.6725 after linear adjustment). Those most widely studied SGA were clozapine (18 papers), risperidone
good linearity was observed in the concentration range of 5-60 μg/mL having regression equation, y = 0.0164x – 0.0071 with correlation coefficient of 0.9998. The percentage recovery of Dapoxetine
contact with the PLGA. The method was linear in the range of between 4 and 14 μg/mL presenting a good correlation coefficient (r = 0.99). The average accuracies of three
dosage form by using simultaneous equation method. The drug obeyed Beer’s law & showed good correlation near to 0.999. Absorption maxima of atorvastatin calcium & fenofibrate were found ... atorvastatin calcium & 2-20…
Conference on Harmonization guidelines. The method follows linearity in the concentration range 5-30μg/ml and 10-60 μg/ml with correlation coefficient value
respectively. The calibration curve was linear in the concentration range of 10-50 μg/ml with coefficient of correlation 0.9993. The percentage recovery for the valsartan was found
found to be linear in the concentration range of 30- 180ppm. The analytical method was validated according to ICH guidelines (ICH Q2b). The correlation coefficient (r2) was found ... value was. The developed method was…
solution in ethanol: distilled water in the ratio of 50:50 (v/v %), With correlation coefficient of 0.999 for the both the drugs. The Beer’s law obeyed the concentration ... Aceclofenac signifies the accuracy of the…
Salbutamol Sulphate. The high values of correlation coefficient (R2) indicated good linearity of calibration curve for both the drugs. The accuracy and precision of method was determined and the method
determination of TP in pure and tablet forms. The method showed a linear response for concentrations in the range of 20-60 μg/mL using Acetonitrile: Phosphate Buffer solution ... flow rate of 0.8 mL/min and retention…
respectively. A linear dynamic range of 10.004-5001.952 ng/ml for APT was evaluated with mean correlation coefficient (r) of 0.9991. The precision of the assay (expressed as coefficient
timing of a substantial proportion of BMAT accrual in long bones during the linear growth spurt suggest an evolutionarily conserved protective effect in which the growing skeleton must benefit from ... parameters were…
method. ANOVA, and Kruskal-Wallis test were used to compare averages according to cases. Linear regression enabled to establish relationships between duration of consumption, quantity of tobacco consumption, as well…
disease. Patients excluded from the study were of ischemic heart and valvular heart disease. Linear Regression Analysis was conducted and R value was computed. Results: R2 value indicates ... Blood Pressure and…
element especially rainfall using Pearson product moment correlation coefficient. The rainfall variability and trend were analyzed using standard anomaly index and simple linear regression respectively. However, the…
design and study of solar energy convention devices. In this study, multiple linear regression models were developed to estimate the monthly average daily global solar radiation using seven parameters during ... mean…
biomass tested are not linearly related to their total hydrogen contents but, directly related to their total Carbon contents. HHV’s calculated from emperical correlations using the elemental contents
close agreement with corresponding experimental values. And a correlation coefficient of 0.9051 for all, shows that there is a linear relationship between the output and target during training
monthly calculated clearness index and monthly sunshine duration were correlated and modeled using four sunshine-based models i.e. linear, quadratic, exponential and power equations. Comparing these models, it was…
minutes. Calibrate curves for Isradipine was linear over the concentration range 50-400 μg/ml with correlation coefficient 0.999. The percentage estimations of the Isradipine in market formulations
group of patients with tinnitus. Statistical analysis included internal validity (Cronbach’s alpha) and linear correlation tests (Pearson coefficient). Results: We evaluated 60 patients with a mean
For authors and organisers
Publish, present and keep up with your field
Find the right journal for your paper and submit your manuscript.