Development and validation of RP-HPLC method for the determination of Atomoxetine Hydrochloride in Pharmaceutical Dosage Forms

Gurmeet Chhabra, Chandraprakas

Abstract

A simple, reliable, specific, accurate and precise reverse phase high performance liquid chromatographic method was developed and validated for the determination of Atomoxetine HCl in pharmaceutical dosage form. Chromatographic separation was carried on RP-C8 column (Phenomenex, size: 250×4.60 mm, particle size 5μm) with a mobile phase composed of acetonitrile and 10 mM disodium hydrogen phosphate buffer with 0.1% TEA (pH 3.0, adjusted with OPA) (55:45, v/v) in isocratic mode at a flow rate of 1mL/min. The detection was monitored at 271nm. The retention time for Atomoxetine was found to be 3.08 min. The method was found to be linear in the range of 50-150μg/mL. The proposed method can be used for the estimation of Atomoxetine HCl in bulk and pharmaceutical dosage forms for routine quality control analysis

Relevant Publications in International Journal of Drug Development & Research