Original Article
Xiaofeng Yang, Fang Wang, Shen
Abstract
An electroanalytical method for determination of salbutamol sulphate was established on basis of enhanced oxidation of salbutamol sulphate at an acetylene black-dihexadecyl hydrogen phosphate composite film modified glassy carbon electrode (AB-DHP/GCE).Under optimalworking conditions, this oxidation current was proportional to salbutamol sulphate concentration range from4.0ï‚´10-7 to 7.5ï‚´10-6mol L-1 and from7.5ï‚´10-6 to 1.0ï‚´10-4mol L-1with a low detection limit of 1.0ï‚´10-7 mol L-1 for 2 min accumulation at open circuit (S/N = 3). The proposed method was applied to the determination of salbutamol sulphate in tablets and the results were satisfying.