Case Report
Kacy A Ramirez1,2,3,4*, Reb
Abstract
Polymerase chain reaction (PCR) is the gold-standard for diagnosing HSVE, but may be inhibited by blood contamination. We mimicked traumatic lumbar puncture and measured its effect on the molecular detection of HSV-1 in CSF. Clinically meaningful reductions in sensitivity were not observed. Pre-PCR processing allows sensitive detection of HSVE despite traumatic lumbar puncture.