Conference abstract · 20 Nov 2013
ArticlePublished 1 Jul 2017
Thyroid shield during brain CT scan: dose reduction and image quality evaluation
Abstract
Select any words in the title or abstract, or press this and choose a sentence.
Introduction: The aim of this study was to investigate the dose reduction to the thyroid gland during routine brain CT examinations. Also, the study compares the quality of the images before and after applying the thyroid shields. Material and methods: An experimental study utilizing head attenuation phantom and multi-slice 16 CT scanner. Dose measurement conducted by thermoluminescent dosimeter (TLD). A circumferential thyroid shielding was used during pre and post scan, images from scan qualitatively assessed for quality parameters such as grayscale, noise, soft tissue, bone details and overall image quality. Results: An average of 45% reduction in the entrance skin dose to the thyroid area was reported. 40-60% dose reduction was achieved at different points along thyroid region. The results of the image quality comparisons between scans done with and without shielding showed that quality of the images was not affected. Significant reduction in the scatter radiation dose to the thyroid during CT head scan when shielding applied. The study proved that application of thyroid shielding would not affect the quality of the images. Therefore, it is highly recommended to be used during brain scan whenever it is possible.
Keywords
Subjects
Radiology & ImagingAsk about this article
Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.
Similar by topic
Editorial · 29 Jul 2025
Advancing CT Imaging: Dose Reduction Techniques and Innovations
Research article · 2 Oct 2012
Radiation dose and image quality evaluation relative to different contrast media using cone-beam CT
Conference abstract · 14 Jul 2016
Determination of beta radiation dose to thyroid from the ingestion of radioiodine (131I) by patients for diagnostic and therapeutic purposes
Conference abstract · 14 Jul 2016
The environmental dose measurements of high dose Iodine-131 treated thyroid cancer patients during hospitalization period.
More from this journal
The newest in Imaging in Medicine.
Article · 31 Dec 2025
Biomedical Advancements in Early Detection: Transforming Healthcare Through Precision and Innovation
Article · 28 Feb 2025
AI Enhanced CPR Revolutionizing Resuscitation with Intelligent Intervention
Article · 28 Feb 2025
Teleradiology: Transforming Medical Imaging in the Digital Age
Follow
New articles from what you follow go into your email digest, once you agree to alert emails.
- JournalImaging in Medicine
- SubjectRadiology & Imaging
- BylineArticles whose byline prints “Abuzaid MM”
- BylineArticles whose byline prints “Elshami W”
- BylineArticles whose byline prints “Haneef C & Alyafei S”
