Scholars Central

Research articlePublished 2017

PDA Device Closure with and without Arterial Access

Authors: Ali A Al-Akhfash, Abdulrahman A Almesned, Abdullah Alqwaiee

Ask about this article

Abstract

Select any words in the title or abstract, or press this and choose a sentence.

Background: PDA device closure can be performed without an arterial access. We are presenting our experience in closing the PDA with and without arterial access. Methods: From February 2012 till August 2014, all patients underwent transcatheter PDA closure were included. Detailed echocardiographic evaluation of the heart with hemodynamic doppler assessment was performed. Results: During the period, 45 patients underwent PDA device closure. All have venous access, 14 patients (31%) have additional arterial access. Since 2013 our protocol is to do PDA device closure without an arterial access except in selected patients when arterial access was considered necessary. Pre-procedure angiograms were performed in tow projections by the venous catheter positioned at the PDA descending aorta junction in 32 patients (71%), and by the arterial accessed catheter in 13 patients (29%). PDA was closed by ado1 device in 25 patients (56%), Oculotech PDA device in 18 patients (40%), and by coils in 2 patients (4.4%). Post PDA device angiograms were performed through the side port of the long delivery sheath. Detailed echocardiographic assessment was performed 2 hrs to 4 hrs after intervention as well as in the next day. No major immediate complications. One patient developed mild pericardial effusion 24 hrs after the procedure. Comparing the differences between those with and without arterial access revealed that the procedure time, the fluoroscopic time as well as the amount of the contrast dose used were less in those with no arterial access. Conclusion: PDA device closure without an arterial access can be performed safely and effectively by experienced interventionist. Patient selection and appropriate pre-intervention detailed echocardiography and procedure planning are essential for accomplishing device closure of PDA. The procedure is simplified and many patients can be discharged on the day of the procedure.

Subjects

Cardiology

Ask about this article

Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.

Try:

Similar by topic

More from this journal

The newest in Interventional Cardiology Journal.

All its articles

Conferences in this field

Upcoming conferences in this field.

Follow

New articles from what you follow go into your email digest, once you agree to alert emails.

  • JournalInterventional Cardiology Journal
  • SubjectCardiology
  • BylineArticles whose byline prints “Ali A Al-Akhfash”
  • BylineArticles whose byline prints “Abdulrahman A Almesned”
  • BylineArticles whose byline prints “Abdullah Alqwaiee”

For authors and organisers

Publish, present and keep up with your field

Find the right journal for your paper and submit your manuscript.

Photo: Pexels