Device closure of the Rupture of Sinus of Valsalva (RSOV) has become a key management strategy over the last two decades whereas surgery has been limited to conditions where device ... closure is not a suitable option…
Background: PDA device closure can be performed without an arterial access. We are presenting our experience in closing the PDA with and without arterial access. Methods: From February 2012 till ... with hemodynamic…
Objective: The study aims to assess feasibility of transcatheter device closure of patent ductus arteriosus in infants weighing less than 5 kg and retrospectively compares the result with ... matched surgical duct…
November 2011 till March 2018, 228 patients were evaluated clinically and echocardiographically for PDA device closure and 201(88%) were found suitable. These 201 patients who underwent transcatheter PDA closure…
Hypertension (PAH). As all the defects were suitable for transcatheter closure, patient underwent successful device closure of VSD by 6/4 mm Amplatzer duct occluder II (ADO II) device ... closure by 6/4 mm Amplatzer…
manipulation. This is a prospective analysis of feasibility, safety and advantages of doing PDA device closure using only venous access under minimal radiation. Background: Taking an arterial access for transcatheter…
Transcatheter device closure of secundum atrial septal defect is a well known option since 1974. The procedure is routinely performed through femoral vein approach but rarely inferior venacava ... options are…
that, experienced interventionists have been continuously reporting successful experiences with PmVSD closure using a variety of off-label device occluders. Recent meta-analyses confirmed the very good outcomes of this…
accomplished with either manual compression (MC) or with the use of a vascular closure device (VCD). While MC is considered the gold standard for mediating arteriotomy closure, numerous VCDs have
treadmill electrocardiographic (ECG) stress testing within 24 h after application of the Angioseal™ vascular closure device. Methods: This is a prospective, randomised, single-center cohort study conducted in a high
Presentation of the transoesophageal echocardiogram for a patient undergoing transcatheter closure of a post infarction ventricular septal defect through a pseudoaneurysm at the basal rather than the apical part…
Introduction: Device closure for septal defects as fossa ovalis ASD, VSD and PDA is now a well-accepted indication. The Amplatzer devices are the most commonly used throughout the world ... defects persisted with no…
rare complication in cardiac surgery. A postoperative iASD was closed with a percutaneous closure device in a 37-year-old patient who had undergone mitral valve replacement via transseptal incision ... hour of the…
safely and effectively managed utilizing a novel technique using the 8Fr Angio-Seal vascular closure device. Methods: Three patients with inadvertent puncture of the subclavian artery during Central Venous Catheter…
saturation of 19%. Mean pulmonary artery pressure was 35 mmHg. Later she underwent successful device closure for ASD with AMPLATZER septal occlude (36 mm) (AGA Medical Corp., Minneapolis ... months revealed normal RV…
Objectives: Percutaneous access is now the norm for many endovascular procedures. Suture-mediated closure devices are commonly used for vessel repair after percutaneous access. Incomplete hemostasis after device…
have ASD with PFO presenting with recurrent cryptogenic strokes need to undergo percutaneous device closure is still a subject of debate. The success rates of PFO closure vary widely ... presenting with recurrent…
year experience with transcatheter closure of Patent Ductus Arteriosus (PDA) in adult using different closure devices. Background: Transcatheter closure of PDA in adults can be challenging because of frequently…
assess the efficacy, outcome, challenges, and complications faced in device closure of infants upto one year of age. Methods: All infants from December 2014 to December 2019 were included ... very safe, effective option…
PDAs are being closed by transcatheter technique safely and efficiently2 .Transcatheter closure of PDA using coil or device is an established method for older children and adults3. Since the first ... design and…
complications. Recently, the Lariat suture delivery device has become available to effectively deliver a single ligature around the left atrial appendage (LAA), with closure rates of 98% at 1 year ... have been observed…