Review article · 2 Jun 2014
Conference abstractPublished 13 Sep 2018
Interfacial impedimetric biosensor
University of Sydney, Australia
Abstract
Select any words in the title or abstract, or press this and choose a sentence.
The immersion of biosensors in body tissue samples inevitably involves the formation of interfaces with body electrolytes. The interfaces are generally viewed as nuisances to recognizances of antibodies to which nanostructures comprising the biosensor surfaces have been sensitized. This is because the interfaces can interfere with sophisticated electronic and chemical constructs comprising the biosensor substrates that transduce and amplify signals generated by targeted antibodies upon binding to complementary antigens anchored within the nanostructures. The interfacial impedimetric biosensor avoids this sophistication but uses electrical impedance spectroscopy (EIS) to characterize electrochemical and physiochemical changes in the interface where antibody-antigen bindings occur. EIS, XPS and water-contact-angle measurements were used to characterize the surfaces and interfaces that alkane nanostructures formed with 1-300 mM KCl electrolytes during the construction of the biosensor. EIS also characterized the interfaces that formed between the nanostructures and the highly doped semiconductor substrate. This confirmed the absence of the usual electric field inducing depletion layers that develop in low doped semiconductor substrates and the absence of dependencies of the interfacial properties on electrolyte concentration. Such remained the case during the construction which commenced with an undecylenic acid nanostructure and progressed through stages of surface modifications with NHS, IgG and glycine. The interfaces that formed with the electrolytes varied but in explainable ways related to thicknesses, surface coverage’s and electronegativity of the modifications as well as electrolyte concentrations. The interfacial recognizance of the targeted anti-IgG was unambiguously confirmed by non-specific binding tests with anti-IgM. Future development stages will be discussed.
Subjects
ChemistryAsk about this article
Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.
Similar by topic
Conference abstract · 13 Sep 2018
Interfacial impedimetric biosensor
Conference abstract · 25 Jun 2021
An impedimetric biosensor development for determination of methyl bromide solution
Conference abstract · 30 Aug 2017
Reduced graphene-oxide based in-line impedimetric biosensor for detecting prostate cancer specific antigen
Research article · 24 Aug 2011
Anti-Prostate Specific Antigen (Anti-PSA) Modified Interdigitated Microelectrode-Based Impedimetric Biosensor for PSA Detection
More from this journal
The newest in Journal of Chromatography & Separation Techniques.
Research article · 15 Sep 2026
An Improved Ion Chromatographic Method for Ultra Trace Level Bromate Analysis in Drinking Water Using Conductivity Detection
Commentary · 7 Jul 2025
Development and validation of a quantification method of urinary free cortisol in 24 hours urine by mass detection.
Commentary · 28 Jun 2025
Advancements and Methodologies of Column Chromatography
Conferences in this field
Upcoming conferences in this field.
Follow
New articles from what you follow go into your email digest, once you agree to alert emails.
- JournalJournal of Chromatography & Separation Techniques
- SubjectChemistry
- BylineArticles whose byline prints “Terry Chilcott”

