Development and validation of a quantification method of urinary free cortisol in 24 hours urine by mass detection.

Authors: Momal Alexe, Dhesse Quentin, Goderniaux Nicolas, Closset Mélanie, Zihao Wang, Colsoul Marie-Lise

Journal of Chromatography & Separation Techniques

Volume 16 · Issue 3 · Pages 1–6

Ask about this article

Abstract

Select any words in the title or abstract, or press this and choose a sentence.

Introduction: Measurement of urinary excretion of corticosteroids and their metabolites is used to evaluate adrenal function in Cushing's syndrome or adrenal cancer. Quantification of Urinary Free Cortisol (UFC) is recommended for Cushing’s syndrome diagnosis. Objective: To develop an easy, reproductible and specific assay technique to quantify UFC by High Performance Liquid Chromatography (UHPLC) and mass detection. Methods: We developed a method based on an UHPLC assay coupled to a single quadrupole mass (QDa) detector. Urines were pre-treated with 1% formic acid and the internal standard before the Supported Liquid Extraction (SLE). Elution was performed with dichloromethane that was then evaporated. Samples were reconstituted with water. The compounds were separated on a HSS T3 column with a gradient elution (0.1% formic acid in water and acetonitrile). Injection volume was 1 μl and the flow rate 0.6 ml/min. We investigated the method regarding linearity, precision, recovery, accuracy, limits of detection and quantification, robustness, and carry-over. Results: The linear range of the method was from 5 μg/l to 1000 μg/l with a determination coefficient of 0.999. The precision was evaluated by the Relative Standard Deviation (RSD) for intra- and inter- assay and was below 9% for both of them. The method showed adequate cortisol recovery (> 90%). The bias between the mean of between-day results and the target value was < 4.7% while the biases between measured and expected values from an external quality control program were <6%. The limit of detection was 0.284 μg/L and the limit of quantification was 0.755 μg/L. The variation representing the method robustness was 4.1% that is lower than the between-day variation. The carry-over was <0.02%. Conclusion: The UHPLC-QDa method with a SLE step for UFC quantification shows adequate performances. It is easy, reproductible and suitable for routine laboratory use.

Subjects

Chemistry

Ask about this article

Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.

Try:

Similar by topic

More from this journal

The newest in Journal of Chromatography & Separation Techniques.

All its articles

Conferences in this field

Upcoming conferences in this field.

Follow

New articles from what you follow go into your email digest, once you agree to alert emails.

  • JournalJournal of Chromatography & Separation Techniques
  • SubjectChemistry
  • BylineArticles whose byline prints “Momal Alexe”
  • BylineArticles whose byline prints “Dhesse Quentin”
  • BylineArticles whose byline prints “Goderniaux Nicolas”
  • BylineArticles whose byline prints “Closset Mélanie”
  • BylineArticles whose byline prints “Zihao Wang”
  • BylineArticles whose byline prints “Colsoul Marie-Lise”