Short communication · 28 Sep 2023
Conference abstractPublished 20 Jun 2018
Impact of mass spectrometer-friendly mobile phases on reverse-phase columns selectivity
Albert Einstein College of Medicine, USA
Abstract
Select any words in the title or abstract, or press this and choose a sentence.
Despite all C18 reverse-phase (RP) columns being based on the same general principle and even with the same non-polar ligand as stationary phase, many RP columns exhibit different selectivity. Due to strong variability in chromatographic behavior, RP columns are extensively tested and compared for LC/UV applications in conjunction with mobile phases containing 0.1% TFA (trifluoroacetic acid) or phosphate, and therefore are not optimal for MS analysis. In the current investigation, we tested 28 different brands of RP columns at different temperatures, and compared their performance and selectivity using MS-compatible mobile phases versus a âÂ?Â?standardâÂ? mobile phase containing 0.1% TFA. Analytes tested were human insulin (~5,808 m.w.), glucagon (~3483 m.w.), C-peptide (~3020 m.w.) and angiotensin 1 (~1,296 mw). To conduct the current study, we built a simple and inexpensive system for automated column testing based on a column switching system from Valco Instruments. While all the tested columns demonstrated low bleed, stable background and also excellent analyte peak shape in the presence of 0.1% TFA, we found that only a fraction of the columns tested could provide good peak shape without TFA for all tested peptide analytes. For some columns, low concentrations of TFA in the mobile phase (which is compatible with LC/MS analysis) may improve peak shape. In many cases however, this did not completely eliminate peak broadening and tailing. We also noticed that silica pore size had only a minor influence on peak shape and utilization of wide pore silica (300A) could not be considered an efficient strategy for improvement of the peak shape for peptide analytes tested. The C18 columns tested demonstrated almost identical selectivity when using 0.1% TFA and 0.015% TFA in the mobile phase, while utilization of MSâÂ?Â?compatible mobile phases for peptide separations with formic acid instead of TFA demonstrated strong, unpredictable variability in column selectivity with changes in the retention order of the peptides used in our study. These results emphasize the necessity of column testing if maximization of LC/MS assay performance (by enhancing of peak shape and maximizing column separation efficiency) is the goal.
Subjects
ChemistryAsk about this article
Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.
Similar by topic
Research article · 2012
Application of Fused-Core Particle Column in Two Dimensional Reversed Phase - Reversed Phase LC/MS Analysis of Biological Samples. Impact of Extra-Column Volume
Conference abstract · 2020
Separation of selected plant origin substances with reversed-phase thin-layer chromatography at controlled mobile phase velocity and stepwise pH gradient
Research article · 26 Aug 2014
Optimization and Validation of a Reverse-Phase High Performance Liquid Chromatography Assay with Ultra-Violet Detection for Measuring Total L-Ascorbic Acid in Food and Beverage Products
Research article · 29 Jun 2013
Development and Validation of a Reverse-Phase HPLC Method for Analysis of Temozolomide in a Capsule Formulation
More from this journal
The newest in Journal of Chromatography & Separation Techniques.
Research article · 15 Sep 2026
An Improved Ion Chromatographic Method for Ultra Trace Level Bromate Analysis in Drinking Water Using Conductivity Detection
Commentary · 7 Jul 2025
Development and validation of a quantification method of urinary free cortisol in 24 hours urine by mass detection.
Commentary · 28 Jun 2025
Advancements and Methodologies of Column Chromatography
Conferences in this field
Upcoming conferences in this field.
Follow
New articles from what you follow go into your email digest, once you agree to alert emails.
- JournalJournal of Chromatography & Separation Techniques
- SubjectChemistry
- BylineArticles whose byline prints “Eduard Rogatsky”

