Computed Tomography (CT) Automatic Exposure Controls (AEC) Testing Protocol Using a CelT Phantom
Abstract
Select any words in the title or abstract, or press this and choose a sentence.
The purpose of this research was to set-up a protocol for using the CeIT elliptical test phantom to test the performance of Automatic Exposure Control (AEC) systems on the CT scanners in use at Aberdeen Royal Infirmary (ARI). These are the GE Lightspeed, GE Optima 6600 and Siemens Somaton Definition in Radiology and the Philips Brilliance in Radiotherapy treatment planning. The variation of image noise and the tube current-time product (mAs) were studied from images obtained from each scanner. Noise was measured using the standard deviation of five selected regions of interest in the images of the phantom obtained from the CT scanners. Normalised percentage noise (noise %) was then calculated to compare how the scanners dealt with image noise with relation to the mAs. The results showed an increase in mAs values (increase in dose) with the phantom and regulation of the noise leading to acquisition of quality images from all three scanners. Offcentering, using the AP scout increased the dose to the phantom when the patient table was above the isocenter and reduced the dose to the phantom when the table was below the isocenter. This shows the importance of patient centering for effective AEC system ’ s dose regulation. Different SPRs also affected the operations of the AEC systems differently, with PA giving more dose followed by LAT and AP in the GE and Philips scanners which were studied on this aspect. The Philips D-DOM modulation kept almost constant dose across the scanning process regardless of the phantom size, hence D-DOM should be used with care. CeLT phantom was useful in studying dose regulation by different AEC systems, hence it is useful in quality control (QC) tests of AEC systems on CT scanners as a testing protocol was formulated from this study.
Keywords
Subjects
Physics & AstronomyAsk about this article
Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.
Similar by topic
Research article · 8 Nov 2021
Determination of Optimum Exposure Factors at Constant Focal Film Distance (FFD) to Produce Quality Skull Radiographs with Minimum Absorbed Dose Using a Skull Phantom
Opinion · 26 Dec 2024
History and Evolution of Computational Phantoms Models for Dose Calculations
Short communication · 31 Aug 2020
Automatic segmentation of infarcted regions from Computed Tomography Perfusion Imaging using 3D Convolutional Neural Network
Research article · 18 Mar 2019
Assessment of automatic tube current modulation technique of multi detectors computed tomography machine in multiphasic examinations computed analysis
More from this journal
The newest in Journal of Medical Physics and Applied Sciences.
Research article · 4 Aug 2026
Frequency-Domain Weak-Signal Analysis for Bias-Controlled Medical Response Assessment
Research article · 14 Aug 2025
A Review of Implementation Challenges and Potentials of an Interoperable e-Health System in LMICS
Commentary · 16 May 2025
AI-Based Image Segmentation Tools for Medical Applications
Conferences in this field
Upcoming conferences in this field.
Follow
New articles from what you follow go into your email digest, once you agree to alert emails.
- JournalJournal of Medical Physics and Applied Sciences
- SubjectPhysics & Astronomy
- BylineArticles whose byline prints “Keolathile Diteko”
- BylineArticles whose byline prints “Rebecca Duguid”
- BylineArticles whose byline prints “Lee Hampson”